AMPLIFIER AUDIO MONITORING
The A/A-AC8 allows monitoring of an amplifier's audio signal. There are trim pots above each amplifier input
which adjust the level of the amp's audio signal that gets mixed to the A/A-AC8's Monitor Outputs. The channel
trim pot's 12 o'clock position corresponds to unity gain, with a maximum of +14 dB gain when fully clockwise.
Any amp channel's audio signal can be routed to either of the two Monitor Outputs. The routing is accomplished
within the MediaMatrix amp control software view. The Monitor 1 and Monitor 2 outputs are differentially driven,
with a maximum output of +22 dBu. External audio inputs with trim pots (maximum unity gain) are provided for
each Monitor channel. These may be used to chain A/A-AC8 monitor busses so that only one set of monitor audio
cables need be routed to the control room.
Figure 4 shows a typical Amp Control audio monitor wiring using two-conductor, shielded audio cable.
figure 4
®
Note: Windows
is a registered trademark of the Microsoft Corporation.
6