NEXA AUDIO AND VIDEO DOOR ENTRY SYSTEM - DISPLAY MODULE
SAFETY PRECAUTIONS
Always disconnect the power supply before installing or making modifications to the devices.
-
-
The fitting and handling of these devices must be carried out by
40 cm away from any other wiring
-
The wiring must run at least
-
On the power supply unit:
Do not overtighten the screws on the connector.
w
Install the power supply unit in a dry and protected place free from the risk of water leaks or sprays
w
wAvoid locations that are humid, dusty or near heat sources.
wEnsure that the air vents are free from obstruction so that air can circulate freely.
wTo avoid damage, the power supply unit must be firmly secured in place.
wTo prevent electric shock, do not remove the cover or handle the wiring connected to the terminals.
CHARACTERISTICS
( )
*
-
Coded display module.
-
Can be combined with "Nexa Modular" and "Inox Modular" door panels.
-
Configuration programmable using a numeric keypad, PC or tablet.
-
Residents list with up to 1,990 contacts.
-
OLED screen.
SYSTEM OPERATION
Display module programming entry and exit:
To enter programming mode, press the key button three times and then enter secret administrator
pin "2718".
10:10
CONFIGURATION
****
To exit programming mode, press button C (cancel) once.
Configuration menu
To enter configuration mode, press the key button three times and then enter the secret
administrator pin "2718" or user pin "4444".
10:10
CONFIGURATION
****
Use to change the system's configuration settings, such as
SYSTEM CONFIG
language, master panel, local address, panel with camera, call to
ACCESS CONTROL
exchange, auto switch-on, set time, etc.
RESIDENT LIST
Puse to configure the access control settings, such as mode and
SYSTEM CONFIG
time of exits, codes, mode and time of entries, unlocking code,
ACCESS CONTROL
RESIDENT LIST
etc.
Use to configure the resident list settings, such as adding, editing
SYSTEM CONFIG
and deleting users.
ACCESS CONTROL
RESIDENT LIST
( )
Programming of monitors/telephones
*
( )
For more information, see the TCODE/CA NEXA user manual (code 50123681).
*
https://doc.golmar.es/search/manual/50123681
2
authorised personnel
.
.
.
2
7
1
8
2
7
1
8
4
4
4
4
or
NEXA AUDIO AND VIDEO DOOR ENTRY SYSTEM - DISPLAY MODULE
MODULE DESCRIPTION
( )
*
a
b
c
d
a. Front.
b.
OLED screen.
c.
Bell button
.
d.
Selection buttons.
Use the arrow buttons to move along the text line.
Use the bell button to confirm the entered text.
Description of the display module's SW1 DIP switch:
Use to reset the special administrator pin to the factory code (2718).
Proceed as follows: Firstly, set dip switch 1 to ON, the module will show the message
RESET PIN, and then set the dip switch to OFF (the pin has now been reset to the
factory code). If the module was locked during this process, it will also unlock the
display module.
Dip switches 2, 3 and 4 have no function.
Description of the Nexa BUS link connector:
The Nexa BUS link connector is located on the bottom right of the back of the display
module.
Connect the cable supplied with the module to other modules using the NEXA Bus:
N3301/AL:
Connect the module to provide the system with access control and a
ð
coded door panel.
N3301A/AL:
Connect the module to provide the system with an alphabetic panel.
ð
EL3002:
Connect to the bus to power information panels (maximum units).
ð
CD-NEXA/BT:
Connect the module to provide the system with a wireless
ð
configuration interface.
Description of the USB connector:
The USB connector enables the door panel to be programmed through the USB port of
a computer. To do so, it is necessary to download the MEMEDIT 5 program from the
web page https://doc.golmar.es. Use to programme door panels and back up
installations to enable the restoring of devices whose memories, due to error or fault,
have been damaged.
Description of the USB connection LED indicator:
The USB connection LED lights up once the computer has detected the module via the
USB interface. It is necessary to install the MEMEDIT 5 program and follow the
installer instructions. If everything has been set up correctly, the LED will light up
every time the module is connected to the computer via USB.
( )
For more information, see the TCODE/CA NEXA user manual (code 50123681).
*