MRRE-4
CONNECTIONS
ANT
Antenna
-
Antenna shield
12-24V
Power supply 12-24V CC
D01
Data output Channel 1
Wiegand : DATA 0
Data Clock : CLOCK
D11
Data output Channel 1
Wiegand : DATA 1
Data Clock : DATA
GND
Ground
D02
Data output Channel 2
Wiegand : DATA 0
Data Clock : CLOCK
D12
Data output Channel 2
Wiegand : DATA 1
Data Clock : DATA
GND
Ground
D03
Data output Channel 3
Wiegand : DATA 0
Data Clock : CLOCK
The recommended cable for the connection of the MRRE-4 reader to the control unit is STP class 5, FTP class 5, or
superior.
The range of Prastel products also includes:
- Access control sector : Stand alone systems, control unit, identification technologies;
- Automation sector : Remote controls, photocells, control units for rolling shutters and gates, safety shoulders, selectors and
flashing indicators, presence detectors;
- Security sector : Barriers for internal and external perimeter protection, alarm systems with or without cable connections,
radio links.
DECLARATION OF CONFORMITY
Prastel declares that the following equipment RECEIVER MRRE-4 IS IN ACCORDANCE with the 99/05/EC (R&TTE) directive
The complete declaration of conformity is available in Prastel.
ENGLISH
D13
GND
D04
D14
GND
EN1
EN2
GND
EN3
EN4
GND
ISMRRE-4_EU_08_15.doc5
Data output Channel 3
Wiegand : DATA 1
Data Clock : DATA
Ground
Data output Channel 4
Wiegand : DATA 0
Data Clock : CLOCK
Data output Channel 4
Wiegand : DATA 1
Data Clock : DATA
Ground
Enable contact Channel 1
Enable contact Channel 2
Ground
Enable contact Channel 3
Enable contact Channel 4
Ground