Descargar Imprimir esta página

TFA Dostmann 60.3518.01 Instrucciones De Uso página 2

Movimiento de radiocontrolado con junto de dos diferentes manecillas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
TFA_No. 60.3518_Anleitung_10_16
Instruction manual
Radio-controlled movement with hands
Kat. Nr. 60.3518.01
Thank you for choosing this instrument from the firm TFA.
1. Before you use it
• Please make sure to read the instruction manual carefully.
• Following the instruction manual for use will prevent damage to the device and loss
of your statutory rights arising from defects due to incorrect use. We shall not be
liable for any damage occurring as a result of not following these instructions.
• Please take particular note of the safety advice!
• Please keep this instruction manual for future reference.
2. For your safety
• This product should only be used as described within these instructions.
Caution!
Risk of injury:
• Not suitable for children under three years of age.
• Small pieces (for example screws) can be fatal if swallowed.
• Keep this instrument and the battery out of the reach of children.
• Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk
of explosion!
• Batteries contain harmful acids. Low batteries should be changed as soon as possible to
prevent damage caused by leaking.
• Wear chemical-resistant protective gloves and safety glasses when handling leaking bat-
teries.
Important information on product safety!
• Do not expose your product to extreme temperatures, vibrations or shocks.
• Protect it from moisture.
• The hands are fragile and easily bendable.
Radio-controlled time reception DCF
The time base for the radio-controlled time is a caesium atomic clock operated by the
Physikalisch Technische Bundesanstalt Braunschweig. It has a time deviation of less than
one second in one million years. The time is coded and transmitted from Mainflingen near
Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of approxi-
mately 1,500 km. Changeover from summer time or winter time is automatic. The quality
of the reception depends mainly on the geographic location. Normally there should be no
reception problems within a 1,500 km radius around Frankfurt.
Please take note of the following
• The recommended distance to any interfering sources like computer monitors or TV sets
is at least 1.5 - 2 meters.
• Inside ferro-concrete rooms (basements, superstructures), the received signal is natu-
rally weakened. In extreme cases, please place the unit close to a window to improve the
reception.
• During nighttime, the atmospheric interference is usually less severe and reception is
possible in most cases. A single daily reception is adequate to keep the accuracy devia-
tion under 1 second.
3. Assembly
• Remove the screw nut and the washer.
• Make sure that the rubber washer does not get lost.
• Now put the movement with the thread in the self-made dial.
• Now attach everything (rubber washer, self-made dial and washer) with the screw nut.
• Pull the protecting foil from the minute hand and the hour hand.
• At first, insert the hour hand and then the minute hand on the thread and set both to
12 o'clock.
• Now attach everything with the second hand and set it also to 12 o'clock.
• Make sure that the hands are not bent during assembly, as this could block the move-
ment.
4. Getting started
• Remove the adhesive tape.
• Now pull out the transport needle.
• Insert a new battery 1,5 V AA, ensure that the battery polarities are correct.
• The unit is ready for use.
• After the initial setup, the pointers show 12 o'clock and the clock trying to receive the
radio signal for 3 - 10 minutes. When the time code is received, the radio-controlled
time will be shown. The clock receives the signal several times a day (1:00; 3:00 and
5:00 am and 1:00; 5:00 and 9:00 pm).
10.10.2016
15:10 Uhr
Seite 2
RoHS
p C N m
www.tfa-dostmann.de
Les instructions en français peuvent être trouvées sur notre site Web.
Le istruzioni in italiano possono essere trovate sul nostro sito web.
De instructies in het Nederlands kunt u vinden op onze website.
Las instrucciones en español se pueden encontrar en nuestro sitio web.
REC button
• You can start the initialization manually.
• Press and hold the REC button for three seconds and the clock will now scan the DCF
frequency signal.
MSET button - Manual setting
• If the clock cannot detect the DCF-signal (for example due to disturbances, transmitting
distance, etc.), the time can be set manually. The clock will then work as a normal quartz
clock.
• Press and hold the MSET button for three seconds.
• Press and hold the MSET button until the desired time is indicated.
• Press the MSET button briefly the pointer moves minute by minute.
• Do not turn the hands directly! The mechanism of the clock could be damaged.
• The manually set time will be overwritten by the DCF time when the signal is received
successfully.
RESET button
• If the unit does not work properly use a pin to press the RESET button.
5. Battery replacement
• Change the battery when the function of the battery becomes weak.
• Insert a new battery 1,5 V AA, ensure that the battery polarities are correct.
• Remove the battery if you do not use the device for a long period of time.
6. Waste disposal
This product has been manufactured using high-grade materials and components which
can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in household
waste.
As a consumer, you are legally required to take them to your retail store or to
appropriate collection sites depending on national or local regulations in
order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labeled in accordance with the EU Waste Electrical and
Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is
obligated to take end-of-life devices to a designated collection point for the
disposal of electrical and electronic equipment, in order to ensure environ-
mentally-compatible disposal.
7. Specifications
Power consumption:
Battery 1 x 1.5 V AA (not included)
Housing dimension:
56 x 37 x 56 mm
Hands set 1
Second hand: 83 mm;
Minute hand: 76 mm;
Hour hand: 54 mm
Hands set 2
Second hand: 81 mm;
Minute hand: 76 mm;
Hour hand: 56 mm
Shaft length
17 mm
Weight:
51 g (instrument only)
Suitable for dials up to 6 mm thickness.
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the
time of going to print and may change without prior notice.
The latest technical data and information about your product can be found by entering your product number on our
homepage.
EU declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 60.3518 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Germany
10/16

Publicidad

loading