13. CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dishwashing soap
with 3 parts water in a spray bottle.
Make sure the control knob is "OFF. " Then, turn the Natural Gas on
at its source.
Spray leak solution on the valve connections, paying particular
attention to the areas indicated by the arrows.
nect and re-test. If you continue to see bubbles after several
attempts, disconnect the Natural Gas Source and Contact Real
Flame ® at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn the gas
source "OFF", wipe away solution and proceed.
NOTE: The proper manifold pressure for this converted appliance is 7" water column.
NOTE: The maximum inlet gas pressure for this unit is 10.5 in wc (2.61 kPa)
The minimum inlet gas pressure for this unit is 3.5 in wc (0.87 kPa)