Montaje.
Assembly.
1
Ensamblaje de la placa en la caja de empotrar a través del muelle bisagra.
Assembly of the panel in the flush-fitted box using the springed hinge.
Atornillar un hilo y un conector tipo "faston"
1
macho a uno de los bornes de la caja de
empotrar.
1
Connect a wire and a male "faston" connector
2
to one of the screw holes of the flush fitting box.
Atornillar el otro extremo del hilo al borne
2
de masa del circuito del teclado.
Connect the other end of the wire to the earth
terminal (-) in the keyboard circuit.
Atornillar otro hilo, más corto, al borne TP
3
3
de la regleta del teclado. El otro extremo
debe terminar en "faston" hembra.
Connect another shorter wire to the TP
terminal in the keyboard circuit. Connect a
female "faston" connector to the other end.
Conexión del TAMPER. Opcional.
TAMPER connection. Optional.
The system operates the door-release when the 4 digit number keyed
in is the same as one recorded.
2
- The total number of differents codes that can be recorded are three for
normal opening and one to open and activate the panic code.
- The factory recorded codes are: 1111, 2222, 3333 and 4444.
- To key in the code press the keys in the correct sequence,
simultaneously a bleep will confirm that each key is pressed. If the code is
correct, the green led lights and door release mechanism is activated for
about four seconds.
If the time between two keys being pressed exceeds 4 seconds, the
system reverts to the initial state and you must begin again.
if a mistake is made keying in the code, press the delete key C, and start
again.
If the panic code is keyed in, first the green led will light and the door will
open as usual, and secondly a relay is activated for 1 minute, which can be
connected to what you want (characteristics: 120 Vac-0'5 A, 24Vdc-1 A). If
the panic code coincides with one of the other three, the relay will not be
activated.
- If the code keyed in is incorrect, the red led lights for four seconds and
the door panel shuts off for this time. After this, the system returns to the
initial rest state.
If five consecutive incorrect codes are keyed in, the red led lights and
the panel shuts off for 1 minute. After this the system returns to the initial
rest state.
- If there is a power failure, the codes are not deleted.
- It is possible to activate a relay (A1, A2 terminals, characteristics: 120
Vac-0'5 A, 24Vdc-1 A) if the panel is opened, this is called TAMPER. It
consists of connecting a wire between terminal TP and an earth point (-),
ensuring that if the panel is pulled out this wire disconnects. Dip4 must also
be placed in the down position.
Operation