PIEZO PUSHBUTTON SWITCHES
1/ COMPLETE MARKING
APEM
BP1 – 55 avenue Edouard Herriot – 82303 CAUSSADE
PBA.AF.000...X
0080 (No of notified body in charge of production control)
Date code (year/week, ex. 09/03)
II 1 G D ; I M1
Ex ia IIC T4 Ga ;Ex ia 1 Ma
Ex ia IIIC T135°C Da IP66
2/ REDUCED MARKING
APEM PBA..AF...X Exi INERIS 07ATEX0043X
3/ INSTRUCTIONS FOR USE
Mounting and other interventions on these switches shall be
carried out by ATEX-trained personnel.
4/ PANEL MOUNTING
Max. torque : 2,5 Nm
- Ø16 mm bushing version:
Ø16,2 mm (.637) cut-out, with hex nut 10-621,
ground connector U5735 and O-ring 10-1155 supplied with the switch.
Fastening with a dynamometric wrench of 19 mm across flats.
- Ø19 mm bushing version:
Ø19,2 mm (.755) cut-out, with hex nut 10-855-5,
ground connector U5736 and O-ring U1961 supplied with the switch.
Fastening with a dynamometric wrench of 22 mm across flats.
- Ø22 mm bushing version:
Ø22,2 mm cut-out (.874), with hex nut 10-856-5,
ground connector U5737 and O-ring U1961 supplied with the switch.
Fastening with a dynamometric wrench of 25 mm across flats.
- Other bushing versions: use specific drawing and accessories supplied
5/ DISASSEMBLY :
reversed operation as assembly.
6/ CONNECTION (switch unpowered)
The equipment connected to the switches is certified intrinsically
safe for the ATEX group corresponding to the use of the switches
according to the input specifications mentioned hereafter.
On red wires (detection part of supports)
- Group I : Ui = 24V AC or DC ; Li= 400 mA ; Pi = 3,15 W ; Ci = 4,3 nF ; Li = 0 µH
- Group II : Ui = 24V AC or DC ; Li =400 mA ; Pi = 1,2 W ; Ci = 4,3 nF ; Li = 0 µH
On the yellow wire (+VLED) compared to blue wire (GROUND) (lighting part)
- Group I : Ui = 24V AC or DC ; Li = 400 mA ; Pi = 3,15 W ; Ci = 0 nF ; Li = 0 µH
- Group II : Ui = 24V AC or DC ; Li = 400 mA ; Pi = 1,2 W ; Ci = 0 nF ; Li = 0 µH
Instruction Notice n°NTPBA007-V04-ENG
The switches shall be connected to ground with the appropriate ground connector and wire
length between switch and operated part shall no exceed 10m. This will ensure EMC according
to the EN61058-1 standard.
7/ ADJUSTMENT
: the switches do not require any adjustment
8/ BRINGING INTO SERVICE
Bringing into service will be made after approval by the project manager, on the base of the reports issued by
the installation engineer or any person entitled to verify the conformity of ATEX installations.
9/ USAGE
Mines full of damp classified M2 and M1, potentially explosive atmospheres of groups IIC and IIA
in areas 0. 1. 2 (T4 temperature class and/or in the presence of combustible dust (T135°C) in
areas 20. 21. 22.
10/ SPECIFIC USAGE
CONDITIONS
The equipment connected to the switches should be certified intrinsically safe for the ATEX
group corresponding to the use of the switches. The output specifications of the equipment
should be compatible with the input specs mentioned in paragraph 6.
11/ MAINTENANCE
: in case of failure or wrong usage, the switches shall be replaced.
12/ ELECTRICAL SPECIFICATIONS
§ Rated voltage: 5V to 24VAC/DC max.
§ Rated current: 0,2A max.
§ Make impulse time: depending on actuation force and speed
.
§ Insulation resistance (OFF): 5 MW mini
§ Contact resistance (ON): 10 W max.
13/ MECHANICAL SPECIFICATIONS
§ Case: stainless steel or brass
§ Multiwire flying lead terminals AWG24, length 300 mm (11.81)
§ Opeating force: 2 to 6N
§ Sealing: IP66 per IEC529 (switches mounted on panel)
14/ ATEX CONFORMITY
§ ATEX directive
2014/34/UE
EN60079-0:2009, EN60079-11 :2012, EN60079-26 :2007, EN50303 :2000
§ Conformity to standards:
15/ MANUFACTURER ADDRESS
APEM 55 avenue Edouard Herriot BP1 82303 CAUSSADE Cedex (France)
Phone : +33 5 63 93 14 98
- Fax : +33 5 63 93 19 03
Temperature range from -40°C to +55°C