Malfunction:
Hot and cold reversed.
Tub filler shower head drips
after shutting off the valve.
Shower insufficiently hot.
No flow of hot or cold water.
Valve body too deep in wall.
Never try to stop dripping by applying excessive force to the handle when closing the valve.
US
Ideal operating pressure:
Max. operating pressure:
Equal pressures cold/warm recommended.
Ideal water temperature:
Max. hot water temperature:
Attention:
Before installation flush pipes thoroughly !
Trouble shooting
Cause:
Hot and cold water supplies
have been connected in
reverse.
Water remains in the shower
piping. (This is normal.)
Incorrect setting of the stop
ring causing a partially opened
cartridge.
Cartridge inlet O-ring seal is
faulty.
Hot limit stop incorrectly set.
Either the hot or cold side is not
fully pressurized, Debris caught
inside the inlet of the cartridge.
No engagement between
handles and plastic driver.
Improper installation.
3 bar (45 psi)
5 bar (70 psi)
65°C (149°F)
90°C (194°F)
Remedy:
Rotate cartridge as described in
„Back-to-back installation"
Allow approximately 3-5 minutes
to drain column, or push lever on
tub spout to the tub fill position.
Reset the hot limit stop ring as
described in rough-in installation.
Check the O-ring for cuts or
damage and replace if necessary.
Refer to the instruction:
Check hot water temperature.
Be sure service stops are both
fully open and system is pressu-
rized.
Remove cartridge and flush out
or remove any debris lodged
inside the hot or cold inlets.
Install extension kit
(include).
15