DISASSEMBLE
1
1
1.
Close valve at vehicle propane gas tank(s).
2.
Disconnect DC wiring from vehicle battery.
3.
Open lower intake vent.
4.
Mark DC wires so you can reinstall in correct location.
5.
Remove DC wires from refrigerator.
To avoid possible propane gas leaks,
WARNING
!
always use two wrenches to loosen and
ATTENTION
tighten gas supply line at manual shut off
valve of refrigerator.
6.
Disconnect AC power cord from receptacle.
7.
Remove gas supply line of the RV 3/8 inch male fl are fi tting of
refrigerator.
8.
Remove screws which fasten lower rear of refrigerator to the
fl oor.
9.
Remove door from refrigerator.
10. Remove screws which fasten refrigerator to cabinet face.
11. Pull refrigerator out of opening far enough to access gas
valve on top of refrigerator.
INSPECT
2
2
1.
Make sure the pressure tap nut is present.
Fig. 2-1
•
If pressure tap nut is not present, replace pressure tap nut
(N3 Recall - Pressure Tap Nut).
2.
Make sure pressure tap nut is not loose. Refer to Fig. 2-1.
•
If nut is loose, use your fi ngers to tighten it.
•
Using a screwdriver, tighten the nut to snug: then turn ap-
proximately 1/8 turn. Refer to Fig 2-2.
Nut MUST be leak tested (below).
WARNING
!
ATTENTION
Printed in U.S.A./Imprimé aux É.-U./Impreso en EE. UU.
Gas Valve
Inspection Instructions
Fig. 2-2
LEAK TEST
3
3
WARNING
!
ATTENTION
1.
Attach gas supply line of the RV to 3/8 inch male fl are fi tting
of refrigerator.
NOTICE
2.
To complete the inspection, open valve at propane gas
tank(s) of vehicle in preparation to test for gas leaks.
WARNING
!
ATTENTION
3.
With gas lines connected, and refrigerator operating in LP
mode, examine gas connections and confi rm connections
have no leaks.
4.
After verifying nut was tightened with leak test or if pressure
tap did not leak, put colored line through both pressure tap
nut and valve body with a paint marker. Refer to Fig. 2-3.
Fig. 2-3
1
Recall # 18E-013
To avoid possible propane gas leaks,
always use two wrenches to loosen and
tighten gas supply line at manual shut off
valve of refrigerator.
If the gas supply line of the RV is not
long enough to allow access to gas valve
with refrigerator pulled forward, use an
auxiliary regulated gas supply to con-
tinue.
Do not use any liquid that contains am-
monia or chlorine.
Do not allow leak detecting solution to
touch electrical components.
Many liquids are electrically conductive
and can cause a shock hazard, electrical
shorts, and in some cases fire.
Part No. / N° de pièce / Pieza n.º 639943C 04.10.2018