HBS 200 Product Overview
120/230/277
PIR
VAC
50/60Hz
Product description
The HBS 200 sensor provides effective lighting
control in high bay aisle way applications. The
sensor contains two dual-element pyroelectric
detectors and is engineered to perform at a
Specifi cations
Voltage
120/230/277 VAC, 50/60 Hz
Load rating
120 VAC: 0-800 watt ballast or Tungsten - 1/4 hp
277 VAC: 0-1200 watt ballast
Time delay
15 sec to 30 min
Light level
.2 - 200 footcandles ; 2 - 2000 lux
Coverage
100 x 13 ft (30.48 x 3.96 m) diameter reach
Environment
IP20 rated, -4°F to +122°F, -20°C to +50°C
Dimensions
3.9 x 3.9 x 2.72 in; 99 x 99 x 69.1 mm
nipple length .62 in (15.75 mm)
5 year warranty
UL and CUL Listed, RoHS Compliant
1
2
5
ON
High
Low
1 2 3 4
4
3
1/2 inch threaded nipple
Light level trimpot
1
4
Lock nuts
Detection lens
2
5
Time delay setting DIP switch
3
Fixture
Aisle
or J Box
IP20
way
Mount
wide range of mounting heights, up to 45 feet. It
mounts directly to a high bay lighting fi xture, or
to a junction box.
10ft/3m
20ft/6.1m
30ft/9.1m
40ft/12.2m
50ft
50ft
15.2m
15.2m
53ft
53ft
16.2m
16.2m
radial
tangential
The HBS 200 has an aisle way coverage of up
to 100 feet when mounted at 40 ft.
- 4 -
Mounting
Placement guidelines
• The HBS 300 and HBS 200 lens must have
a clear, unobstructed view of the detection
area.
• Sensor should be 6 to 8 feet away from
heating/cooling supply ducts.
End of fi xture mounting
The HBS 300 and HBS 200 typically mount to
a 1/2" knockout at the end of a high/low bay
lighting fi xture. The sensor's lens should be
mounted below the bottom edge of the fi xture.
The EM 1 Extender Module is recommended
if the knockout at the end of the fi xture is
located greater than 1/2" from the bottom
edge of the fi xture.
Junction box mounting
If mounting to the end of a fi xture is not
possible, the HBS 300 and HBS 200 can
be mounted to any junction box with a 1/2"
(trade size) knockout. This may be necessary
if the fi xture location of the control area has
an obstruction that would block the view of
the sensor (for example: racking is directly
beneath the fi xture).
• Ideal mounting height is up to 45 feet.
• Sensor must be mounted on a stable platform.
Fixture
HBS sensor
Fixture
EM 1
HBS sensor
Junction
box
HBS sensor
- 5 -