Putting Into Service; Operation; Error Messages; Technical Data - ADE Ramona Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 5
Thank you for purchasing this high-quality product made by ADE. You have acquired a
set of scales that meet the highest technical standards and are of proven quality.
Please read these operating instructions carefully before using the product for the first
time and keep them in a safe place where you can find them whenever you need the
information contained in the instructions.
1.

Putting into service

Inserting the batteries / Replace the batteries:
Open the lid of the battery compartment on the bottom of the
scale and remove the battery safety strip. Please observe the
correct polarity of the batteries (+/-).
To replace the batteries open the lid of the battery compartment. Move the battery at the
recess downwards. In this way, the batteries will be easy to take out. Make sure that you
do not bend the contact. Insert the new batteries (2 x CR 2032) and close the lid of the
battery compartment.
Safety guideline s:
Ensure that no objects fall onto the scales; otherwise, the scale
may be damaged.
Only use a damp cloth to clean the scales. Never use solvents
or abrasive cleaners. Do not put the scale under water. You
must clean all the plastic parts of the scales immediately after
they come into contact with grease, spices, vinegar or any other
strongly spiced or coloured foods. Avoid any contact with citric
acid.

2. Operation

Switch ing on the scales:
Place the scales on a firm, level base. Press down on the scales' surface for about
2 seconds with a pressure of 500 g to switch the scales on. The display initially shows at
first all characters. After the scales have stabilised, they display "0 g" / "0.0 oz" /
"0: 0.0 lb: oz" or "0 ml", depending on the setting. The scales are now ready to weigh.
2
Units of weight:
Touching the UNIT-panel allows you to change country-specific units of weight
(g = grammes / oz = ounces / lb: oz = pounds: ounces / ml = millilitres). Please ensure
that the scales are set to the appropriate units of weight for you.
Tare Func tion:
Touching the ON/TARE-panel allows you to set the scales to "0 g". Place a bowl, for
example, on the platform of the scales, touch the ON/TARE-panel and in this way set the
scales back to "0 g". You can repeat this procedure as often as you like until the total
capacity of the scales (5 kg) has been reached. After you remove the item(s) to be
weighed, the total weight is displayed as a minus value.
Automatic/manua l switch-off of the sca les:
If the displayed weight does not change within about 60 seconds, the scales switch
themselves off automatically. To conserve batteries life, you can switch off the scales
manually by touching the ON/TARE button for approximately two seconds.

3. Error Messages

"Lo"
=
Indication that the battery is flat – Please replace the batteries with two
CR 2032.
"EEEE"
=
Overload display – The 5 kg maximum capacity of the scales has been
exceeded. Immediately remove the load from the scales; otherwise, the
load cell could be damaged.

4. Technical Data

Carrying power x graduation: Max. 5 kg x 1 g
Dimensions:
approx. 180 mm x 230 mm x 20 mm
Batteries:
2 x CR 2032 (included)
Subject to technical changes due to further-development of the product.

5. Guarantee

ADE guarantees to rectify any defects due to material or manufacturing defects by means
of repair or replacement free of charge for a period of three years. In the case of guarantee
claims, please return the scales together with the sales slip to your retailer and stating the
reasons for the claim.
CE conformity
This device is interference-supp ressed in accordan ce with
the app licable EU direc tive 2004/108/EC
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ke 1128

Tabla de contenido