Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

IMPORTANT INSTRUCTIONS -
QZ Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
1.
Read all instructions before installing or using range hood.
2.
Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
3.
Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
4.
Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
5.
Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
6.
When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO
ATTICS, CRAWL SPACES, OR GARAGES.
7.
This unit must be grounded.
8.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
6728005 Rev. A 4-07
OPERATING MANUAL
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
WARNING:
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambéing food (ie. Crepes Suzette, Cherries Jubilee, Peppercorn
Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
WARNING:
THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
I. You know you have a Class ABC extinguisher, and you already
know how to operate it.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING:
DUCTWORK.
www.airkinglimited.com
Range Hood
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
TO REDUCE THE RISK OF INJURY TO PERSONS IN
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
1

Publicidad

Tabla de contenido

Solución de problemas

loading

Resumen de contenidos para AirKing QZ Serie

  • Página 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL QZ Series Range Hood READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Página 2 INSTALLATION INSTRUCTIONS the kitchen) with the addition of a model RF34 Charcoal Filter (not included) or vented through a 7" round duct with the addition of a Unpack hood from the carton and confirm that all pieces are present. model E-22a or RDC7 Duct Collar (not included) (Figure 3). In addition to the range hood you should have: 1 - Aluminum Grease Filter Vertical...
  • Página 3 Hood Body E-22A/RCD7 Damper Hot (Black) White from Lamp Ground White from Motor Figure 7 Figure 5 Install the wire compartment cover and tighten screw. Make sure Install an approved wire connector to the electrical knockout of all wiring is securely contained within the wire compartment. the hood and guide the electrical cable through the hood, allowing Ducting at least 6"...
  • Página 4: Troubleshooting Guide

    Turn switches to the “OFF” position and restore power. Test that once a month. Reverse the instructions in the “Finishing the Installation” the light and the fan are operating properly. section of the instructions to remove filter. If the grease filter becomes damaged, replace with Air King Model GF-06 Grease Filter.
  • Página 5: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Description Replacement Part # Description Replacement Part # Blade Clip 5S4109001 Speed Control 5S4199017 Fan Blade 5S4109002 Light Switch 5S4199018 Motor 5S2109001 Wrapper - 30" 5S1424030 Motor Screw 5S4109003 Wrapper - 36" 5S1424040 Filter GF-06 5S4109004 Bushing 5S1999016 #6 AB Screw 5S1999004...
  • Página 6: Hotte De Cuisine

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Séries QZ Hotte de Cuisine LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Página 7 INSTRUCTIONS D’INSTALLATION sans conduit (recirculation de l’air dans la cuisine) avec l’addition d’un filtre au charbon modèle RF34 (non inclus) ou soufflé au travers Déballer la hotte de sa boîte et confirmer que toutes les pièces d’un conduit rond de 17,78 cm (7 po) avec l’addition d’un clapet sont présentes.
  • Página 8 section à onglets du clapet sous le corps de la hotte et en vissant les deux vis fournies. Pour un conduit rond de 17,78 cm (7 po), fixer soit un clapet modèle E-22A ou RCD7 (non inclus) à la hotte avec les 3 vis fournies (Figure 5).
  • Página 9: Guide De Dépannage

    Mettre les interrupteurs en position « HORS (OFF) » et rétablir une fois par mois. Renverser les instructions dans la section «terminer l’alimentation. Tester que la lampe et le ventilateur fonctionnent l’installation» des instructions pour retirer le filtre. Si le filtre à graisses devient endommagé, le remplacer par un Filtre à...
  • Página 10 DIAGRAMME DES PIÈCES DE REMPLACEMENT Description # de pièce de remplacement Description # de pièce de remplacement Agrafe d’hélice 5S4109001 Contrôle de Vitesse 5S4199017 Hélice de ventilateur 5S4109002 Interrupteur de lumière 5S4199018 Moteur 5S2109001 Bande de recouvrement - 76,20 cm (30 po) 5S1424030 Vis du moteur 5S4109003...
  • Página 11: Información General De Seguridad

    INSTRUCCIONES IMPORTANTES – MANUAL DE OPERACIÓN Campana de Serie QZ Extracción LEA Y GUARDE ESTAS INSTRUCCIONES LEA CUIDADOSAMENTE ANTES DE INTENTAR MONTAR, INSTALAR, OPERAR O MANTENER EL PRODUCTO DESCRITO. PROTÉJASE A USTED MISMO Y A LOS DEMÁS OBEDECIENDO TODA LA INFORMACIÓN DE SEGURIDAD. ¡EL HECHO DE NO CUMPLIR CON LAS INSTRUCCIONES PODRÍA RESULTAR EN DAÑOS PERSONALES Y/O A LA PROPIEDAD! CONSERVE LAS INSTRUCCIONES PARA REFERENCIA FUTURA.
  • Página 12 INSTRUCCIONES DE INSTALACIÓN tuberías (re-circula el aire hacia la cocina) con el agregado de un Filtro para Carbón modelo RF34 (no incluido) o ventilado a través Desempaque la campana de la caja y confirme que todas las piezas de un tubo redondo de 7" con el agregado de un Collar para Tubos están presentes.
  • Página 13 con lengüetas debajo del cuerpo de la campana y asegurándola con los dos tornillos provistos. Para tubos redondos de 7", asegure un Collar para Tubos modelo E-22A o RCD7 (no incluidos) a la campana con los tres tornillos provistos (Figura 5). Cuerpo de la Campana E-22A/RCD7...
  • Página 14: Mantenimiento

    Coloque los interruptores en la posición “APAGADO” y restaure el con detergente una vez al mes. Invierta las instrucciones en la suministro eléctrico. Compruebe que la luz y el ventilador estén sección “Terminando la Instalación” para retirar el filtro. Si el filtro funcionando correctamente.
  • Página 15: Diagrama De Repuestos

    DIAGRAMA DE REPUESTOS Description # de pièce de remplacement Description # de pièce de remplacement Sujetador de la hélice 5S4109001 Control de velocidad 5S4199017 Aspa del ventilador 5S4109002 Interruptor de la luz 5S4199018 Motor 5S2109001 Envoltorio - 30" 5S1424030 Tornillo del motor 5S4109003 Envoltorio - 36"...
  • Página 16 6728005 Rev. A 4-07 www.airkinglimited.com...

Tabla de contenido