Pleasant Hearth GFB100 Instrucciones Importantes
Pleasant Hearth GFB100 Instrucciones Importantes

Pleasant Hearth GFB100 Instrucciones Importantes

Soplador de sistema de chimenea

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT
FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF
LIFE.
WARNING: THIS PRODUCT IS ONLY FOR USE WITH MODELS
SPECIFIED IN THIS MANUAL BY THE MANFACTURER. ANY OTHER
USAGE OR INSTALLATION NOT SPECIFIED IN THIS MANUAL IS
PROHIBITED.
This Product can expose you to chemicals including Diisononyl phthalate (DINP) which is known
to the State of California to cause cancer and Di-isodecyl phthalates (DIDP) which is known to the
State of California to cause developmental harm.
For more information go to www.p65Warnings.ca.gov
Questions, problems, missing parts?
Before returning to your retailer, call our call our customer service depart-
ment at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or
email us at customerservice@ghpgroupinc.com.
80-10-101
This fan is a CSA approved component compatible
IMPORTANT INSTRUCTIONS
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Fireplace System Blower
with these GHP Group Fireplace Systems only:
VFF2-PH(20D)(20DB)(20D-C)(CPD-2T)
VFF2-PH(26D)(26D-T)(IMD-2H)
VFF2-PH(32DR)(32DR-H)(FSDR-2C)
VFF-PH(20D)(20DB)(20D-C)(CPD-2T)
VFF-PH(26D)(26D-T)(IMD-2H)
VFF-PH(32DR)(32DR-H)(FSDR-2C)
WARNING
1
MODEL #: GFB100
IMGFB - 2018-04-24

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Pleasant Hearth GFB100

  • Página 1 Fireplace System Blower MODEL #: GFB100 This fan is a CSA approved component compatible with these GHP Group Fireplace Systems only: VFF2-PH(20D)(20DB)(20D-C)(CPD-2T) VFF2-PH(26D)(26D-T)(IMD-2H) VFF2-PH(32DR)(32DR-H)(FSDR-2C) VFF-PH(20D)(20DB)(20D-C)(CPD-2T) VFF-PH(26D)(26D-T)(IMD-2H) VFF-PH(32DR)(32DR-H)(FSDR-2C) IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT...
  • Página 3: Safety Information

    SAFETY INFORMATION SAVE THESE INSTRUCTIONS WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and must be plugged directly into a properly grounded three-prong receptacle. Read all instructions before using this appliance. If possible always unplug this appliance when not in use. Do not operate any heater with a damaged cord or plug or after the appli- ance malfunctions, has been dropped or damaged in any manner.
  • Página 4: Package Contents

    PACKAGE CONTENTS Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and diagram under. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact our Technical Service Department at 1-877-447-4768. Parts List REF # PART #...
  • Página 5 ASSEMBLY INSTRUCTIONS WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and must be plugged directly into a properly grounded three-prong receptacle. Firebox must be disconnected from gas supply and removed from mantel before installing fan accessory.
  • Página 6 ASSEMBLY INSTRUCTIONS Important: Insert the wires marked with AUTO, OFF and MAN into line slot on the right corner. Keep wires close to the bottom and guide to the front using the bottom access. Insert two wires’ female plugs marked with T1 and T2 (black and yellow) into two male ports on Temperature Sensor.
  • Página 7 ASSEMBLY INSTRUCTIONS Insert the blower link (male plug) into the power link (female port). Important: Bind wires with cable tie (G), and attach cable tie (G) into the fixed hole from the in side of the Outer Casing. Do the same with the wires through the bottom access.
  • Página 8 ASSEMBLY INSTRUCTIONS Push Rocker Switch (E) into Control Panel and secure. Secure the Green Ground wire to the Grounding screw hole from Screw the inside with the screw. Green Ground Wire Check that all wires are secure and reattach Blower Access Panel to Outer Casing.
  • Página 9: Electrical Wiring Diagram

    OPERATING INSTRUCTIONS Using Rocker Switch, turn blower on and check for operation. Turn on Rocker Switch to the desired position. In the MAN position it will remain constantly on. AUTO position will be controlled by the Temperature Sensor. To stop the opera- tion turn Rocker Switch to the OFF position.
  • Página 10: Troubleshooting

    MAINTENANCE OF MOTORS WARNING: Make sure all power to the appliance is turned OFF before proceeding. Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation. The motor used on the flame blower is pre- lubricated for extended bearing life and requires no further lubrication.
  • Página 11 This limited warranty is extended to the original retail purchaser of this heater and warrants against any years years...
  • Página 12 GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...
  • Página 13: Soplador De Sistema De Chimenea

    Soplador de sistema de chimenea NÚM. DE MODELO GFB100 Este ventilador es un CSA componente aprobado, compatible conlos Sistemas de chimenea de GHP Group solamente: VFF2-PH(20D)(20DB)(20D-C)(CPD-2T) VFF2-PH(26D)(26D-T)(IMD-2H) VFF2-PH(32DR)(32DR-H)(FSDR-2C) VFF-PH(20D)(20DB)(20D-C)(CPD-2T) VFF-PH(26D)(26D-T)(IMD-2H) VFF-PH(32DR)(32DR-H)(FSDR-2C) INSTRUCCIONES IMPORTANTES POR FAVOR, LEA ESTE MANUAL ANTES DE LA INSTALACIÓN Y USO DEL DISPOSITIVO ADVERTENCIA: SI NO SE SIGUE CON EXACTITUD LA INFORMACIÓN...
  • Página 15: Información De Seguridad

    INFORMACIÓN DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES ADVERTENCIA: Este aparato está equipado con un enchufe de tres terminales (conexión a tierra) para su protección contra peligro de choque eléctrico y debe ser conectado directamente en un receptáculo de tres terminales con conexión a tierra apropiada.
  • Página 16: Contenido Del Paquete

    CONTENIDO DEL PAQUETE Antes de comenzar a ensamblar este producto, asegúrese de que todas las piezas estén presentes. Compare las piezas con las listas de contenido del paquete y el diagrama a continuación. Si hace falta alguna parte o se encuentra dañada, no intente Llame a nuestro departamento de servicio ensamblar, instalar u operar el producto.
  • Página 17: Instrucciones De Ensamblaje

    INSTRUCCIONES DE ENSAMBLAJE PRECAUCIÓN: La caja de fuego debe estar desconectada del suministro de gas y retirada del marco antes de instalar el accesorio de ventilador. Póngase en contacto con una persona de servicio calificada para hacer esto. Retire el panel de acceso del soplador y el panel acceso inferior.
  • Página 18 INSTRUCCIONES DE ENSAMBLAJE Importante: Inserte los cables marcados con AUTO, OFF y MAN en la ranura de línea en la esquina derecha. Mantenga los cables cerca del fondo y guíe hacia el frente usando el acceso inferior. Inserte dos enchufes hembra de dos cables marcados con T1 y T2 (negro y amarillo) en dos puertos machos en el sensor de temperatura.
  • Página 19 INSTRUCCIONES DE ENSAMBLAJE Inserte el enlace del soplador (enchufe macho) en el enlace de energía (puerto hembra). Importante: Ate los cables con amarres de cable (G), y sujete los amarres de cable (G) en agujeros en la parte trasera de la cubierta exterior. Sujete uno en el agujero cercano a la cubierta y otro en el agujero cercano al fondo.
  • Página 20 INSTRUCCIONES DE ENSAMBLAJE Presione el interruptor oscilante (E) en el panel de control y asegure. Asegure el cable verde de toma de tierra al agujero del tornillo de tierra Tornillo por dentro con el tornillo Tierra verde cable Compruebe que todos los cables estén seguros y reinstale el panel de acceso del soplador en la cubierta Tornillo...
  • Página 21: Diagrama De Cableado Eléctrico

    INSTRUCCIONES DE OPERACIÓN Usando el interruptor oscilante, encienda el soplador y compruebe la operación. Coloque el interruptor oscilante en la posición deseada. En la posición MAN permanecerá constantemente encendido. La posición AUTO será controlada por el sensor de temperatura. Para detener el funcionamiento, coloque el interruptor oscilante en la posición OFF.
  • Página 22: Mantenimiento De Motores

    MANTENIMIENTO DE MOTORES ADVERTENCIA: Asegúrese de que toda la energía al dispositivo esté APAGADA antes de proceder. Siempre desconecte el dispositivo de la fuente de energía principal y deje que se enfríe antes de cualquier operación de servicio. Los motores usados en el soplador de llama están prelubricados para prolongar la vida del cojinete y no requieren lubricación adicional.
  • Página 23: Garantía

    Garantía GARANTÍA LIMITADA: Esta garantía limitada se extiende al comprador original al por menor de este conjunto de calentador y garantiza contra cualquier defecto en materiales y mano de obra durante un periodo de (2) años a par tir de la fecha de venta al por menor. GHP Group, Inc., a su opción, proporcionará piezas de reemplazo o reparará...
  • Página 24: Registro De La Garantía

    REGISTRO DE LA GARANTÍA IMPORTANTE: Le urgimos que llene su tarjeta de registro de la garantía en el plazo de catorce (14) después de la fecha de compra También puede registrar su garantíaen internet en www.ghpgroupinc.com. Complete el número de serie. Conserve esta porción de la tarjeta para sus registros.

Tabla de contenido