NuTone Heavy Duty HD50NT Manual Del Usuario
NuTone Heavy Duty HD50NT Manual Del Usuario

NuTone Heavy Duty HD50NT Manual Del Usuario

Ventiladores de cielo raso

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

CEILING VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the ser-
vice disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring
must be done by a qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combus-
tion and exhausting of gases through the
flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating
equipment manufacturer's guideline and
safety standards such as those published
by the National Fire Protection Associa-
tion (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or
shower, it must be marked as appropriate for
the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected
branch circuit.
8. Never place a switch where it can be
reached from a tub or shower.
9. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
3. Please read specification label on product
for further information and requirements.
TYPICAL INSTALLATIONS
POWER CABLE
MOUNTING TABS
CEILING
JOIST
HOUSING
CEILING
GRILLE
MATERIAL
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
POWER CABLE
MOUNTING
TABS
HOUSING
I
"
"
CEILING
GRILLE
JOIST
MATERIAL
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
INSULATION*
(Place around and
over Fan Housing.)
FAN
HOUSING
POWER
CABLE*
Seal gaps
around
Housing.
4-IN. ROUND
DUCT*
*Purchase
separately.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
MODELS HD50NT • HD80NT
POWER CABLE
2 x 4
CEILING
JOIST or
TRUSS
CEILING
MATERIAL
HOUSING MOUNTED
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
ADDITIONAL
*
FRAMING
*
Additional framing must be a 2x6
(minimum height).
"
I
"
JOIST
OR
Seal duct
joints with
4-IN.
tape.
ROUND
ELBOWS*
Page 1
ADDITIONAL
MOUNTING
FRAMING
TABS
CEILING
JOIST or
TRUSS
HOUSING
GRILLE
TO 2x4 TRUSS
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
*
2 x 4

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone Heavy Duty HD50NT

  • Página 1 MODELS HD50NT • HD80NT Page 1 CEILING VENTILATORS READ AND SAVE THESE INSTRUCTIONS TYPICAL INSTALLATIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC POWER CABLE SHOCK, OR INJURY TO PERSONS, OB- POWER CABLE ADDITIONAL SERVE THE FOLLOWING: MOUNTING FRAMING MOUNTING TABS TABS 1.
  • Página 2: Typical Installations

    MODELS HD50NT • HD80NT Page 2 TYPICAL INSTALLATIONS INSTALL THE HOUSING (continued) (continued) New Construction 4" ROUND DUCT POWER CABLE MOUNTING HOUSING SUSPENDED GRILLE CEILING MATERIAL SUSPENDED CEILINGS Housing hung with wires - 3-point mount. INSTALL THE HOUSING 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
  • Página 3: Connect The Wiring

    MODELS HD50NT • HD80NT Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM B L K B L K Existing Construction O N / O F F S W I T C H W H T B L K L I N E W H T W H T...
  • Página 4: Service Parts

    NUTONE ONE YEAR LIMITED WARRANTY NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Página 5: Ventiladores De Cielo Raso

    MODELOS MODELS HD50NT • HD80NT Página 5 Page 5 VENTILADORES DE CIELO RASO LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INSTALACIONES TÍPICAS PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO CABLE DE ALIMENTACIÓN CABLE DE ALIMENTACIÓN ALETAS DE ESTRUCTURA SIGUIENTE:...
  • Página 6: Instalación De La Cubierta

    MODELOS MODELS HD50NT • HD80NT Página 6 Page 6 INSTALACIÓN DE LA INSTALACIONES TÍPICAS (continuación) CUBIERTA (continuación) Construcción nueva CONDUCTO REDONDO DE 4" (10.2 CM) CABLE DE ALIMENTACIÓN ALETA DE CUBIERTA MONTAJE MATERIAL DEL REJILLA TECHO SUSPENDIDO TECHOS SUSPENDIDOS Cubierta montada con cables. Montaje de tres puntos. INSTALACIÓN DE LA CUBIERTA - POR FAVOR NOTE - 3.
  • Página 7: Conexión Eléctrica

    MODELOS MODELS HD50NT • HD80NT Página 7 Page 7 CONEXIÓN ELÉCTRICA INSTALACIÓN DE LA CUBIERTA (continuación) DIAGRAMA ELÉCTRICO Construcción existente N E G N E G I N T E R - R U P T O R B L C E N C E N D I D O / A P A G A D O N E G...
  • Página 8: Piezas De Servicio

    Esta garantía le proporciona derechos legales específicos, y usted puede también tener otros derechos, los cuales varían de estado a estado. Esta garantía reemplaza todas las garantías anteriores. Para calificar en la garantía de servicio, usted debe (a) notificar a NuTone al domicilio que se menciona abajo o al teléfono:1-800-543-8687, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o pieza.

Este manual también es adecuado para:

Heavy duty hd80nt

Tabla de contenido