Equipo electrónico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SC230E
DIP1 DEFAULT SETTINGS
22
TERMINAL 12 AS SAFETY EDGE ACTIVE ONLY IN OPEN
PHOTOCELL DURING OPENING ENABLED
ENERGY SAVING - SAFETY DEVICES TEST ENABLED
DIP2 DEFAULT SETTINGS
23
TERMINAL 17 AS ELECTRIC LOCK SIGNAL, SEE FIG.
TERMINAL 11 AS SAFETY EDGE ACTIVE DURING CLOSE AND OPEN
ADDITIONAL ATTEMPTS AFTER SECURITY DEVICES INTERVENTION ENABLED
ANTI CRUSHING ENABLED
FAST CLOSING ENABLED
DECELERATION ENABLED
AUTOMATIC CLOSING ENABLED
PRE-FLASHING ENABLED
WORKING LOGIC
TRAVEL LEARN MODE
UNUSED
TEMINAL 8 AS «PAUSE» COMMAND
SOFT START ENABLED
120CM SLOW DOWNS
ENCODER FUNCTIONING
ENABLED
ELECTRONIC BRAKE ENABLED
DIP1
TERMINAL 12 AS STOP
ANTI CRUSHING DISABLED
FAST CLOSING DISABLED
DECELERATION DISABLED
AUTOMATIC CLOSING DISABLED
PHOTOCELL DURING OPENING DISABLED
ENERGY SAVING - SAFETY DEVICES TEST DISABLED
PRE-FLASHING DISABLED
OFF-OFF = STEP BY STEP WITH STOP
ON-OFF = STEP BY STEP
OFF-ON = AUTOMATIC
ON-ON = DEAD MAN
DIP2
NORMAL FUNCTIONING
UNUSED
TERMINAL 17 AS WARNING LIGHT
TERMINAL 8 AS PEDESTRIAN COMMAND
TERMINAL 11 AS SAFETY EDGE ONLY ACTIVE DURING CLOSE
SOFT START DISABLED
60CM SLOW DOWNS
TIME FUNCTIONING ENABLED
ELECTRONIC BRAKE DISABLED
ADDITIONAL ATTEMPTS AFTER SECURITY DEVICES INTERVENTION DISABLED