SSS Siedle ZAM 600-01 Informacion De Producto página 9

Ocultar thumbs Ver también para ZAM 600-01:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
ZAM 670-...
for Siedle Access
Scope of supply
• ZAM 670-...
• Terminal block
• This product information
Terminal assignment ZAM 670-...
b1
Supply 12 V AC,
c1
15–32 V DC
D1
Data transmission with dig-
D2
ital call and Vario bus data
transmission
K1
Switching output
("speech" status display)
K2
Switching output
("door opened" status
display)
K3
Switching output
("call" status display)
COM Switching output, collective
contact for K1–3
IN1
Input to external actuation
("door opened" status
display)
L01
RF output
L02
H/L
Impedance high/low
S1
Loudspeaker signal from the
S2
door loudspeaker module
Remarks
• In the Access system, the termi-
nals S1 and S2 are only required
if an induction loop system or an
AF amplifier is connected at termi-
nals L01, L02.
• To allow the full performance
scope to be used in the Access
system, you must operate the Access
server with the current software
status (from version 1.3.0).
Terminal plans
6 Connection at the Access system
Notes on the wiring diagram
a) The supply limits of the ATLC/
NG 670-... must be observed.
For detailed information, see
Planning and System Manual
Access Professional
7 In the ZAM 670-..., the status
contacts are connected via a collec-
tive contact.
The information on the Vario bus is
transmitted via the RS485 protocol.
The contacts are connected in par-
allel to the relevant status LED.
Activating the acoustic feedback
With the ZAM 670-..., activation of
the additional acoustic feedback for
the status messages is carried out
using the Access server administra-
tion.
Connection of an external induc­
tion loop system or AF amplifier
Audio OUT: The AF output signal is
applied to terminals L01, L02.
The output impedance is 10 kOhm.
By inserting a bridge from L01 to
H/L, the output impedance is set
from 10 kOhm to 600 Ohm – in
accordance with a 0 dB interface.
8 To output the NF signal on the
ZAM 670-... the audio signal must
be connected to the S1, S2 termi-
nals.
Specifications ZAM 670-...
Output impedance NF signal:
10 kOhm, with bridge 600 Ohm
Operating voltage: 12 V AC,
15–32 V DC
Operating current: 70 mA
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
99 x 99 x 26
Outputs (K1, K2, K3, COM):
32 V, 1 A
Français
Application
Module d'affichage d'état avec
notification optique et acoustique.
Un symbole rétroéclairé par LED
signale les états "Appel",
"Non joignable", "Parler" et
"Ouverture de porte".
La signalisation optique peut, en
option, être renforcée par une
confirmation acoustique.
Tension électrique
L'installation, le montage et l'entre-
tien d'appareils électriques ne
doivent être réalisés que par un
spécialiste en électricité.
Service
Des informations concernant le
changement de module figurent
dans la notice de montage de la pla-
tine de rue Vario.
1/2 Signalisation optique et
acoustique
1 Appel
2 Non joignable
3 Porte ouverte
4 Parler
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zam 670-0

Tabla de contenido