MODEL 8140 FRESH AIR VENTILATOR
VENTILATION CONTROLLER
FILTER
COVER
WALL MOUNT
BRACKET LOCATION

SAFETY INSTRUCTIONS

1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.
1. Read all instructions before beginning installation.
2. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed by a qualified service
technician.
TABLE OF CONTENTS
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Introduction and Compliance Statement . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Install Electrical Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Ventilator Location and Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Mount the Ventilator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Mount Intake Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Install Ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Model 8140NC - Wiring to Various Controls . . . . . . . . . . . . . . . . . . . . . . . .5
Model 8140NC - Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Model 8140NC - Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .6
10012996 B2208006B 7.19
Model 8140 and 8140NC
Fresh Air Ventilator
Installation and Operating Instructions
HIGH PRESSURE PORT
WARNING
CAUTION
READ AND SAVE THESE INSTRUCTIONS
MODEL 8140NC FRESH AIR VENTILATOR
LOW PRESSURE PORT
INLET COLLAR AND
NORMALLY CLOSED
POWER DAMPER
Model 8140 - Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Model 8140 - Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Measure Delivered Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Model 8140 - Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Model 8140 - Rater/Inspector Verification . . . . . . . . . . . . . . . . . . . . . . . . . 10
Model 8140 - Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Filter Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1
Internal Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
VENTILATION TERMINALS
JOIST MOUNT
BRACKET LOCATION
English 1
OUTLET
COLLAR

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Aprilaire 8140

  • Página 1: Tabla De Contenido

    Model 8140 – Wiring the Control to the HVAC System . . . . . . . . . . . . . . .6...
  • Página 2: Introduction And Compliance Statement

    INTRODUCTION AND COMPLIANCE STATEMENT The Model 8140 and 8140NC Fresh Air Ventilators are designed to bring in precisely the right amount of outdoor air into today’s efficiently designed homes . Duct the inlet of the ventilator to an outdoor air intake and duct the discharge to the HVAC system, then simply plug the unit in, set the amount of needed ventilation and select the desired temperature limits .
  • Página 3: Ventilator Location And Orientation

    VENTILATOR LOCATION AND ORIENTATION CAUTION FIGURE 2 – CLEARANCES FOR SERVICING 1. Mount the blower with the lowest, exposed moving parts at least 8 feet (2.4 m) above floor or grade level. 2. Mount the blower at least 3.3 feet (1.0 m) from any accessible opening of the duct.
  • Página 4: Mount Intake Hood

    MOUNT INTAKE HOOD Install a weather tight hood with a bird screen . Cut a hole in the exterior wall that is large enough to fit 6" insulated flexible duct through with minimal compression of the insulation . Pull the duct through the hole and attach the flex duct to the collar of the hood .
  • Página 5: Model 8140Nc - Wiring To Various Controls

    MODEL 8140NC – WIRING TO VARIOUS CONTROLS Suggested Controls: • Aprilaire IAQ Control Models 8910, 8910W or 8920W • Aprilaire Thermostat Models 8620 or 8620W • Model 8120A or 8120X Digital Ventilation Controller Select the diagram that corresponds to the control to be used . Wire the controls to the HVAC equipment and any other IAQ accessory in accordance with the literature provided with the control .
  • Página 6: Model 8140Nc - Test Mode

    MODEL 8140NC – SEQUENCE OF OPERATION Refer to the installation manual provided with the control that is wired to the Model 8140NC . MODEL 8140 – WIRING THE CONTROL TO THE HVAC SYSTEM NOTICE FIGURE 9 – REMOVE CONTROL FROM MOUNTING PLATE...
  • Página 7: Model 8140 - Connecting The Control To The Ventilator

    O = REV. VALVE, COOLING GS = FAN INPUT GH = FAN OUTPUT MODEL 8140 – CONNECTING THE CONTROL TO THE VENTILATOR Plug the Control Connector into the back of the control at the location shown in FIGURE 12 . Route FIGURE 12 –...
  • Página 8: Model 8140 - Test Mode

    60 minutes/hour or you can 90-2354 simply place a jumper between the VENT terminals of the ventilator . Model 8140 – Turn on the ventilator by using the “Up” button to increase the ventilation setting TABLE 3 – DELIVERED AIRFLOW CORRESPONDING TO MEASURED PRESSURE to 60 MIN .
  • Página 9: Model 8140 - Set Up

    . IMPORTANT NOTE: The 8140 control senses the temperature and humidity of the outdoor air. To prevent extended periods of inactivity, set the control mode to codE, or if setting to cFrt (comfort), set the RH limits to OFF.
  • Página 10: Model 8140 - Rater/Inspector Verification

    (Floor Area ft .01) + (No. of Bedrooms + 1) MODEL 8140 – SEQUENCE OF OPERATION “CODE” SETTING The control will turn on ventilation with a heating, cooling or fan call for the set number of minutes during a one-hour cycle period . If the outdoor temperature is above the high temperature ventilation limit, ventilation will not occur with a cool or fan call, but if it is below the low temperature ventilation limit it will occur with a heat call .
  • Página 11: Filter Cleaning

    90-2241 90-2241 INTERNAL SCHEMATICS FIGURE 16 – MODEL 8140 INTERNAL SCHEMATIC CAPPED RED & WHITE WIRES ARE LOCATED INSIDE THE FILTER DOOR TO POWER THE CONTROL (R & C TERMINALS) FROM THE POWER PCB ASSEMBLY. USE ONLY IF THE VENTILATON CONTROLLER WILL NOT BE WIRED TO THE HVAC SYSTEM.
  • Página 12: Limited Warranty

    WARRANTY REGISTRATION Visit us online at www.aprilaire.com to register your Aprilaire product . If you do not have online access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name and address to: Research Products Corporation, P . O . Box 1467, Madison, WI 53701 .
  • Página 13: Instrucciones De Seguridad

    Modelo 8140: cableado del control al sistema de HVAC . . . . . . . . . . . . . . . .
  • Página 14: Introducción Y Declaración De Cumplimiento

    . El sistema de control también se asegura que la ventilación se produzca durante no menos de una hora de cada cuatro . Si se instalan y se configuran de manera adecuada, los ventiladores de aire fresco modelo 8140 y 8140NC cumplirán con los requisitos mecánicos de ventilación de:...
  • Página 15: Ubicación Y Orientación Del Ventilador

    UBICACIÓN Y ORIENTACIÓN DEL VENTILADOR PRECAUCIÓN FIGURA 2: ESPACIOS PARA REALIZAR EL MANTENIMIENTO 1. Con la menor cantidad de piezas móviles expuestas, instale el soplador al menos a 8 pies (2.4 m) del piso o del nivel del suelo. 2. Instale el soplador a una distancia mínima de 3.3 pies (1.0 m) de cualquier abertura desde la que se pueda acceder al conducto.
  • Página 16: Instalación Del Extractor De Admisión

    INSTALACIÓN DEL EXTRACTOR DE ADMISIÓN Instale un extractor hermético con una malla contra pájaros . Haga un agujero en la pared exterior que sea lo suficientemente grande como para que ingrese un conducto flexible aislado de 6 in con una compresión mínima del aislamiento .
  • Página 17: Modelo 8140Nc: Cableado Para Varios Controles

    MODELO 8140NC: CABLEADO PARA VARIOS CONTROLES Controles sugeridos: • Los modelos con control de Calidad del aire interior (Indoor Air Quality, IAQ) 8910, 8910W o 8920W de Aprilaire • Los modelos de termostato 8620 o 8620W de Aprilaire • Controlador digital del sistema de ventilación modelo 8120A o 8120X Seleccione el diagrama que corresponda de acuerdo con el sistema de control que se utilizará...
  • Página 18: Modelo 8140Nc: Modo De Prueba

    MODELO 8140NC: SECUENCIA DE FUNCIONAMIENTO Consulte el manual de instalación que se proporciona con el sistema de control que está conectado al modelo 8140NC . MODELO 8140: CABLEADO DEL CONTROL AL SISTEMA DE HVAC AVISO FIGURA 9: RETIRO DEL SISTEMA DE CONTROL DE LA PLACA DE MONTAJE Desenchufe el sistema de HVAC durante el cableado para evitar que ocurran cortocircuitos eléctricos.
  • Página 19: Modelo 8140: Cómo Conectar El Control Al Ventilador

    GS = ENTRADA DEL VENTILADOR GH = SALIDA DEL VENTILADOR MODELO 8140: CÓMO CONECTAR EL SISTEMA DE CONTROL AL VENTILADOR Enchufe el conector del sistema de control en la parte posterior del control en la ubicación que se muestra en FIGURA 12: CONEXIÓN DEL SISTEMA DE CONTROL AL VENTILADOR...
  • Página 20: Modelo 8140: Modo De Prueba

    1. Asegúrese de que el ventilador esté enchufado y conectado a un sistema de control externo (modelo Baja 8140NC) o que el sistema de control integral esté conectado al sistema de HVAC (modelo 8140) . 2. Utilice conductos flexibles de 1/4 in para conectar un indicador de presión configurado para medir pulgadas de columna de agua (a veces se muestra como “in .
  • Página 21: Modelo 8140: Configuración

    . NOTA IMPORTANTE: el sistema de control del modelo 8140 detecta la temperatura y la humedad del aire exterior. Para evitar que se produzcan períodos prolongados de inactividad, establezca el modo del sistema de control en codE (Código), o si la configuración está establecida en cFrt (Comodidad), establezca los límites de RH en OFF (Apagado).
  • Página 22: Modelo 8140: Verificación Del Evaluador/Inspector

    MODELO 8140: VERIFICACIÓN DEL EVALUADOR/INSPECTOR Para verificar la configuración del tiempo de ventilación, presione el botón Select (Seleccionar) para desplazarse por las opciones de Required Continuous CFM (CFM constantes necesarios) y Measured CFM (CFM medidos) calculados para esta instalación . Si algún valor no coincide con el valor esperado, se debe ingresar al menú de configuración para modificar la superficie cubierta, la cantidad de habitaciones o los CFM medidos .
  • Página 23: Limpieza Del Filtro

    90-2241 ESQUEMAS INTERNOS FIGURA 16: ESQUEMA INTERNO DEL MODELO 8140 LOS CABLES RECUBIERTOS DE COLOR ROJO Y BLANCO SE ENCUENTRAN DENTRO DE LA PUERTA DEL FILTRO Y SE UTILIZAN PARA ALIMENTAR EL SISTEMA DE CONTROL (TERMINALES R Y C) A PARTIR DEL TABLERO DE CIRCUITO IMPRESO DE CONTROL DE POTENCIA.
  • Página 24: Garantía Limitada

    GARANTÍA LIMITADA El ventilador de aire fresco de Research Products Corporation de Aprilaire® cuenta con una garantía de cinco (5) años a partir de la fecha de instalación que cubre defectos materiales o de mano de obra . La obligación exclusiva de Research Products Corporation bajo esta garantía es la de suministrar, sin cargo, un repuesto para cualquier pieza que esté dañada dentro del período de los cinco (5) años mencionado y usted o su proveedor original puede devolverlo hasta treinta (30) días después del período de 5 (cinco) años a Research Products Corporation, Madison, Wisconsin 53701, junto con el número de modelo y la fecha de...