Signals:
B
During normal operation:
- Flashing light: indicates that the interphone is receiving
a call (from outdoor entrance panel or from an intercom-
municating device).
- Steady light: ringtone muted (User Away function).
- Steady light flashing every 10s: if calls have been
made from the entrance panel while the ringtone was
muted, the LED flashes a number of times equal to the
number of calls received from the entrance panel (up to
4 calls are memorised). The flash log is reset when the
ringtone volume is restored.
During programming:
- Flashing light: indicates programming mode.
C
During normal operation:
- Steady light: indicates that the door is open if the sen-
sor has been installed on at least one entrance panel
and connected between terminals PA and M.
During adjustment:
- Flashing light: indicates that ringtone selection or vol-
ume adjustment is in progress.
Settings
H
Brightness setting: allows the screen brightness to be
adjusted.
I
Contrast setting: allows contrast to be adjusted.
L
Colour setting: allows the colour to be adjusted.
Connection terminal block:
1, 2
Two pairs of terminals for Two-Wire bus
E+, E- Additional power supply for monitor with power supply unit type
6923.
12V
Connection of additional chime (positive reference 12V).
CH
Connection of additional chime (call repetition).
FP
Input for door call button (with reference to terminal M).
M
Earth reference.
GB
L
Fig. 2
I
H
Dip-switch for Bus termination
Connection terminal block