Malfunctions

Malfunctions
Blue LED on the mixer tap
is not lighting up
Water does not run when
the sensor is activated
Hot water mode is
not functioning
The set water quantity
for filter or hot water is
significantly different
Status LED on the boiler
is glowing orange
Possible causes
- Mixer tap is not receiving
electricity
- The volume wheel is at "0"
- Connecting hoses
are kinked
- Connecting hoses are
wrongly attached
- The volume wheel is at "0"
- Filter head is connected in
the incorrect flow direction
- Electronic devices are in
front of the sensor
- The volume wheel is at "0"
- Malfunctions in
the control box
- System error in the boiler
Error correction
- Connect the power supply unit of the control
box to the mains electricity
- Check the connections on the control box
- Turn the volume wheel and set
an amount > "0"
- Connect hoses without kinks
- Connect the hoses according to
the assembly instructions
- Turn the volume wheel and set
an amount > "0"
- Check whether the filter cartridge has
been connected against the flow direction,
and change the flow direction
- Remove electronic devices
- Turn the volume wheel and set
an amount > "0"
- Unplug the power supply of the control box,
wait for 1 minute, then plug it in again.
- Unplug the power supply of the boiler, wait
for 1 minute, then plug it in again. Afterwards
press the button again.