HARDWARE TEST
To do a hardware reset, remove the battery and
•
re-install it.
If the adaptor does not function normally or
•
appears, please go through the reset process to
restart the adaptor.
SETTING TORQUE VALUES
LOW VOLTAGE INDICATOR
If the battery voltage is too low, the meter will display a
battery symbol and then turn off. Replace batteries.
Er0
When
shows during power-on process,
it means this adaptor has been applied to more than
110% of maximum torque.
Er4
In angle mode, if the adaptor does not reset
successfully for a period of time,
shown. Press to do zero-reset again and place the
adaptor on a flat surface to reset.
RESETTING PRESET VALUES
Press
to power on.
•
Do not apply force on adaptor.
•
Target torque or angle will be shown.
•
Press
to select the torque unit or degree
•
(angle mode) and then press
target value.
To select preset values press the button
•
repeatedly until desired preset is selected.
Press
to reset adaptor.(suggested)
•
Start to rotate adaptor.
•
Watch out the warning LED, sounds and LCD to
•
stop rotation.
Tracking Mode
In track mode, LCD displays the current torque
•
value.
After release force, the LCD value will return to 0.
•
Peak Mode
In peark mode, LCD displays the maximum torque
•
value attained.
After release of force, the LCD shows the
•
maximum value that can be reached. (flashing)
DATA12, DATA14, DATA38
N-m
M T
indicator
will be
to set
Er5
shows that the adaptor does not
work functionally, please do hardware
reset. Refer to "HARDWARE RESET".
Er--
In angle mode, if the adaptor rotates too fast,
will be shown. Press to zero reset the adaptor.
Now press
•
press
to clear it.
Angle operation
In angle mode, LCD displays the angle rotated after
•
the reaching over 5% of the rated maximum torque.
Now press
•
to clear it.
5
to record maximum torque value, or
to record angle value, or press