Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions and Replacement Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
The Aqua Pro pumps are general use
centrifugal water pumps.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
DANGER
!
Never run engine in an
enclosed area. Exhaust gases
contain deadly poisonous carbon
monoxide, which has no odor or taste.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Gas Powered
Water Pump
WARNING
!
Do not use to pump flammable
or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not
use in flammable and/or explosive
atmospheres. Pump should only be used
with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal injury
and/or property damage.
2. Observe all safety precautions for the
handling of the fuel.
WARNING
!
Do not refuel a hot engine.
Fuel spilled on a hot engine
could result in a fire or explosion. Do not
refuel a running engine.
3. Pump should be located and should
rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.
Be sure pump is on
NOTICE
secure footing so it
doesn't fall over.
4. Do not use torches or apply excessive
heat, fire or flames to this pump as an
explosion may result.
5. Before working on the unit, insulate
the wire from the spark plug,
disconnect the spark plug wire and
mount it on the grounding clip.
Complete pump
NOTICE
and piping system
MUST be protected against below
freezing temperature. Failure to do so
could cause serious damage and voids
the warranty.
6. Do not run pump dry. Water is
required to lubricate the shaft
seal.
7. Pumping chemicals or corrosive
liquids with this pump may shorten
GPH550PRO
Need
Assistance?
Call Us First!
1-877-278-2797
the life of the pump and may be
hazardous to the operator.
8. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors at a safe distance from
the work area.
d. Make workshop child-proof with
padlocks, master switches, and by
removing starter keys.
9. Always use a suction strainer with this
pump to filter large material.
Installation
This pump is designed to be self-
priming when installed and operated as
specified below.
1. The pump should be placed as close
as possible to the liquid being
pumped. A pump with 20 foot
suction lift will not remove water as
quickly as a pump with 5 foot
suction lift (Figure 1).
20 Ft.
Suction Lift
5 Ft.
Suction
Lift
Figure 1
2. Suction hose and fitting must be
airtight.
322600-013 03/06

Publicidad

loading

Resumen de contenidos para Aqua PRO GPH550PRO

  • Página 1 Description WARNING hazardous to the operator. 8. Personal Safety: The Aqua Pro pumps are general use Do not use to pump flammable centrifugal water pumps. or explosive fluids such as a. Wear safety glasses at all times gasoline, fuel oil, kerosene, etc.
  • Página 2 Operating Instructions and Replacement Parts List 9. Add water to the priming port on recommended. Installation the pump (See Figure 3). Continue Do not use this pump for suction lifts (Continued) adding water until the water level is over twenty-five feet. approximately 3 inches from the An air leak in the NOTICE...
  • Página 3 Operating Instructions and Replacement Parts List Performance Information Semi-Trash Pump Performance GAS PERFORMANCE Model Discharge Head GPH550PRO Gallons/Hour 16800 14400 12000 9000 4620 FEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPE Gallons Per Minute Pipe Size 11.9 20.2 30.5 14.3...
  • Página 4 - Serial number (if any) 101 Production Drive - Part description and number as shown Harrison, OH 45030 3" HOSE KIT 550 PUMP 5.5 HP HONDA OHV GPH550PRO LAY FLAT DISCHARGE HOSE 2" SUCTION STRAINER SUCTION HOSE PART #16511 PART #66036 PART #16510-002 •...
  • Página 5 Operating Instructions and Replacement Parts Manual For Replacement Parts, call 1-877-278-2797 Please provide following information: Address parts correspondence to: - Model number Aqua Pro Systems - Serial number (if any) 101 Production Drive - Part description and number as shown Harrison, OH 45030...
  • Página 6 Limited Warranty For one year from date of purchase, Aqua Pro (”Wayne Water Systems“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Aqua Pro to be defective in materials or workmanship.
  • Página 7: Bomba Hidráulica Con Motor A Gasolina

    PELIGRO AVISO No haga funcionar nunca el Todo el sistema de bomba y tubería Las bombas Aqua Pro son bombas motor en un área encerrada. DEBE protegerse de las temperaturas de hidráulicas centrífugas de uso general. Los gases de escape contienen congelación.
  • Página 8: Instalación

    Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Tuberías y mangueras muy largas Todas las conexiones de succión deben Instalación y con curvas reducen la presión ser a herméticas. Si la bomba no ceba, (Continuación) generada por la bomba. controle que no haya pérdidas en la tubería o empalmes de succión.
  • Página 9 Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Características de Rendimiento Rendimiento de Bomba Semi-Residual RENDIMIENTO A GASOLINA Modelo Altura de descarga GPH550PRO Galones/Hora 16800 14400 12000 9000 4620 PÉRDIDA DE ALTURA POR FRICCIÓN EN 100 PIES (30 m) DE TUBERÍA DE PLÁSTICO Diá.
  • Página 10 - Descripción y número del repuesto como se indica Harrison, OH 45030 U.S.A. JUEGO DE MANGUERA DE 3" (7,5 CM) BOMBA 550 5.5 HP HONDA OHV GPH550PRO CEDAZO DE SUCCIÓN DE MANGUERA DE SUCCIÓN MANGUERA EN LONA PARA DESCARGA 2" (5 CM)
  • Página 11 Por repuestos, llame al 1-877-278-2797 Sírvase proporcionar la siguiente información: Dirija su correspondencia sobre repuestos a: - Número de modelo Aqua Pro Systems - Número de Serie (de haberlo) 101 Production Drive - Descripción y número del repuesto como se indica Harrison, OH 45030 U.S.A.
  • Página 12: Garantía Limitada

    Garantía Limitada Durante un (1) año a partir de la fecha de compra, Aqua Pro (“Wayne Water Systems”) reparará o reemplazará, según lo decida, para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (el “Producto”) que después de un examen sea(n) hallada(s) por Aqua Pro como defectuosa(s) en su material o mano de obra.