VOLTAGE SELECTION SWITCH
OR
Voltage select screw should be placed next to
correct voltage setting (115 VAC shown)
SKID TANK INSTALLATION
16"
C
U S
LIS TE D
300F7776 ADAPTER
6 7/8"
DIRECT MOUNTING INSTALLATION
C
U S
LIS TE D
16"
JUCTION BOX
PUMP
SKID TANK
1 1/2" SUCTION PIPE
JUNCTION BOX
PUMP
300F7776 ADAPTER
2" STD. PIPE COUPLING
1 1/2" SUCTION PIPE
2" PIPE
GROUND LINE
TANK LINE
END OF PIPE MUST BE AT
LEAST 3" OFF BOTTOM OF
T A N K
2
TYPICAL ISLAND INSTALLATION
32 1/2"
1 7/8"
1/2" BOLTS
ELECTRICAL
CONDUIT
7 25/32"
4" DIA.
PUMP
CLEARANCE HOLE
FRONT
LAYOUT FOR
BASE ANCHOR BOLTS
WIRE DIAGRAM
For Models FR300, FR301, FR310, FR311 ONLY
BLACK
AC
BROWN
AUX.*
WHITE
NEUTRAL
GREEN
GROUND
WARNING:
*
AUX. WIRE IS LIVE WIRE!
The AUX. lead wire is insulated and enclosed when shipped. Do
not connect this wire without first verifying the 'ON' line voltage of
the wire for compatibility to the equipment to be installed. Maximum
amperage on wire is 1 ampere. The wire must be insulated and
enclosed in the junction box if not used.
PUMP
300F7778 COUPLER
600F2130 PEDESTAL PIPE
1 1/2" SUCTION PIPE
ELECTRICAL CONDUIT
700F3060 PUMP BASE
CONCRETE ISLAND 36" SQUARE
TANK LINE
END OF 1 1/2" OR LARGER SUCTION
PIPE MUST BE AT LEAST 3" OFF
BOTTOM OF TANK
MOTOR