JABSCO 50870 Manual Del Usuario página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
Cyclone
Pump
Stainless Steel DC
Motor/Pump Unit
Features & Benefits
Heavy duty robust design
Stainless steel construction
Long life DC motor
Silent running
Anti-clog impeller design
Long life mechanical seal
Single tool servicing
Specifications
Recommended duty Max. 30 minutes duty (Min. 30 minutes off)
Motor life 2500 hours
2m suction lift when wet
Relevant Standards:
ISO 8846 MARINE and USCG Regulations for Ignition Protection
ISO 8849 MARINE Bilge Pump Standard
Performance Curve
Typical performance based on pumps running at
12.8V and 25.6V DC
1.4 (20.3)
1.2 (17.4)
1.0 (14.7)
0.8 (11.6)
0.6 (8.7)
0.4 (5.8)
0.2 (2.9)
0
0
WARNING: Do not pump petrol or fluids
with a flash point below 37°C (98°F).
Explosion and death may occur.
Installation Instructions
The Cyclone can be mounted on any flat surface.
The pump must be installed below the lowest fluid level to
maintain flooded suction.
Fit pump in a dry, well ventilated position.
Use rubber grommets provided to minimise vibration.
If mounted vertically, ensure the motor is above the pump head.
Use 3/4" pipe fittings with PTFE pipe joint tape or compound.
Plastic fittings should not be used if pump is installed below
the waterline..
WARNING: All marine pumps discharging over-
board must be installed with the overboard
discharge well above both static and heeled
waterlines. Flooding and death may occur.
20 (5.3)
40 (10.6)
Flow – lpm (gpm)
60 (15.9)
80 (21.1)
100 (26.4)
120

Publicidad

Tabla de contenido
loading

Tabla de contenido