Descargar Imprimir esta página
Leviton 57000 Serie Instrucciones De Instalación
Ocultar thumbs Ver también para 57000 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

LIMITED TEN YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else
that this product at the time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for ten years from the purchase date. Leviton's
only obligation is to correct such defects by repair or replacement, at its option, if within
such ten year period the product is returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing Co., Inc., Att: Power Quality
Customer Support, 860 Harold Place, Chula Vista, CA 91914, U.S.A. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an improper environment,
overloaded, misused, opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels or instructions. There are
no other or implied warranties of any kind, including merchantability and fitness for a
particular purpose, but if any implied warranty is required by the applicable jurisdiction, the
duration of any such implied warranty, including merchantability and fitness for a particular
purpose, is limited to ten years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform this warranty obligation. The
remedies provided herein are the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.
For Technical Assistance Call:
1-800-648-3332 (U.S.A. Only)
www.leviton.com
DI-031-57000-20A
1
All manuals and user guides at all-guides.com
DI-031-57000-20A
DANGER
HIGH VOLTAGE
Haute Tension
Multi-Phase Transient Voltage Surge Suppressor
Cat. No. 57000 Series
For main distribution and branch circuit panels
INSTALLATION INSTRUCTIONS
Limiteur de surtensions transitoires polyphasé
Gamme 57000
Pour panneaux de branchement ou de dérivation
DIRECTIVES
Dispositivos Protectores de Sobrecargas
Nos. de Cat. Serie 57000
Para paneles de distribución de circuitos principales o derivados
INSTRUCCIONES DE INSTALACION
8/25/03, 4:23 PM
DI-031-57000-20A

Publicidad

loading

Resumen de contenidos para Leviton 57000 Serie

  • Página 1 Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ten years from the purchase date. Leviton’s...
  • Página 2 Leviton está libre de defectos en materiales o fabricación por un período de diez años desde la fecha de la compra original. La única obligación de Leviton es corregir tales defectos ya sea con reparación o reemplazo, como opción, si dentro de tal período de diez años el producto pagado se devuelve, con la prueba de compra fechada y la descripción del...
  • Página 3: Tabla De Contenido

    All manuals and user guides at all-guides.com vez la energía CA, el DEL rojo de desactivación de batería y el DEL amarillo ENGLISH de batería baja se iluminarán. El interruptor de desactivación de batería debe presionarse momentáneamente para activar la batería. Esto será indicado al Table of Contents apagarse los DEL de desactivación de batería y batería baja.
  • Página 4: Description

    All manuals and user guides at all-guides.com de iluminación en los DELs indica ya sea una pérdida de energía o un fusible DESCRIPTION quemado debido a transitorios excesivos, como los que surgen de un golpe The 57000 TVSS Panel Protection System is a high-performance Transient de rayo.
  • Página 5 IT IS RECOMMENDED THAT THE 57000 TVSS PANEL PROTECTION INSTRUCCIONES DE SERVICIO SYSTEM BE INSTALLED BY A QUALIFIED ELECTRICIAN. Procedimiento para el Servicio del DPS 57000 de Leviton: Lea TO INSTALL: cuidadosamente estas instrucciones así como el procedimiento de reemplazo WARNING: TO AVOID FIRE, SHOCK, OR DEATH;...
  • Página 6 Procedimiento de Aislamiento de Problemas, impreso en la parte interna 4. Cutting Access Holes: Cut holes for conduit in panel using approved de la puerta, contacte la Asistencia Técnica de Leviton al 1-800-648-3332 metal cutting tools. Prevent any metallic filings from remaining inside the (sólo en EAU.)
  • Página 7: Conexión Remota

    All manuals and user guides at all-guides.com también alimentar una carga. En este caso, los interruptores deben ser apropiados a esta carga. El Panel DPS debe ser conectado a esos interruptores a través de un interruptor de desconexión tripolar de 30 Conduit amperios como mínimo.
  • Página 8 #10 AWG (35 in.-lbs.), #8 AWG (40 in.-lbs.), El Panel DPS 57000 de Leviton debe ser montado tan cerca como sea #3 - #6 AWG (45 in.-lbs.). posible al panel de interruptores para proporcionar la máxima protección de Connecting wire lengths from the circuit breaker panel to the 57000’s...
  • Página 9 All manuals and user guides at all-guides.com computer room or an area of electronic instrumentation. Note that protection components are in parallel with any loads. The TVSS Panel should be mounted as close as possible to the circuit Conducto breaker panel to provide maximum surge protection to other branches fed by other circuit breakers within the circuit breaker panel.
  • Página 10: Remote Connection

    All manuals and user guides at all-guides.com Table 1 - Diagnostic Indicator Functions: Beeper Battery Disable Self Test List of the diagnostic functions of the 57000 ("Audio Alarm") ("Low Battery") ("Test") V(L-L) series panels. V(L-L) Mode Fault Beeper Remote Module Battery Disable Disable Disable Disable Momentary V(L-L)
  • Página 11: Servicing Instructions

    OFF. If problems are V(L-N) encountered that can not be resolved using the Problem Isolation Procedure printed on the inside of the enclosure door, contact Leviton Technical Support: 1-800-648-3332. 12. Diagnostic Test: Press and hold down the test button. The Red warning...
  • Página 12: Otras Precauciones

    All manuals and user guides at all-guides.com Diagnostic Indicator Functions: Table 1 lists the diagnostic functions of the generadas por la conmutación de cargas, como las de motores eléctricos que 57000 series panels. se prenden y se apagan; a lo externo, pueden ser causadas por la Module Diagnostics: Each module contains two Green LEDs.
  • Página 13: Descripción

    All manuals and user guides at all-guides.com LED, audible beep tone, and remote transmitter are activated. When multiple DESCRIPCIÓN Green module LEDs are OFF, it is probable that the unit’s diagnostic circuitry is El Sistema de Protección Series 57000 es un Dispositivo Protector de being powered from the battery.
  • Página 14: Français

    All manuals and user guides at all-guides.com ESPAÑOL FRANÇAIS Table des matières Tabla de Contenido SECCION PAGINA SECTION PAGE DESCRIPCION ....................25 DESCRIPTION ....................12 CARACTERISTICAS ..................25 CARACTÉRISTIQUES ..................12 INSTALACION ....................25 INSTALLATION ....................12 INSTRUCCIONES DE SERVICIO ..............33 MAINTENANCE ....................
  • Página 15 • Modules enfichables remplaçables, qui facilite l’entretien. de la dite période de dix ans, à la Manufacture Leviton du Canada Limitée, au soin du service de l’Assurance Qualité, 165 boul. Hymus, Pointe-Claire, (Québec), Canada •...
  • Página 16: Autres Mises En Garde

    All manuals and user guides at all-guides.com ou provenir d’une source externe. À l’interne, les surtensions peuvent êtres lumières vertes des modules sont allumés, il s’agit d’une panne au niveau de générés par la commutation de charges, comme de moteurs électriques qui la pile plutôt qu’ait celui des modules ou des fusibles.
  • Página 17 All manuals and user guides at all-guides.com peuvent êtres attribuables à l’absence de courant sur la phase principale ou au 3. S’identifier le système électrique en usage (Delta ou Y) : il critique grillage d’un fusible des suites d’un bris de module causé par une surtension assortir le module DPS et les voltages de la ligne.
  • Página 18: Directives D'ENtretien

    V(L-L) «Test» est appuyé. DIRECTIVES D’ENTRETIEN Procédure d’entretien relative au DPS 57000 de Leviton : on doit lire Module 1 attentivement les directives suivantes, de même que celles qui sont relatives au remplacement des fusibles ou des modules, avant de procéder à...
  • Página 19 All manuals and user guides at all-guides.com • Un trou bouché de 2,2 cm sur le flanc gauche de l’enclos est fourni pour la connexion de le télé avertisseur. Voir les instructions pour la méthode de connexion. Conduit 9. Installation de la pile : une pile alcaline de 9 V est comprise. La fonction de ça pile est à...
  • Página 20 Les Figures 4 et 5 illustre systèmes de Le panneau DPS 57000 de Leviton devrait être fixé le plus proche connexion alternes qui emploient disjoncteurs (dédié ou mitoyen), ou un possible au panneau de disjoncteurs, afin de fournie limitation de interrupteur débrancher.