3.1 Mounting onto TS 35 DIN rails
(Page 46, Fig. 1)
3.2 Pluggable electronic components for range alteration
(depending on model)
(Page 46, Fig. 2)
1. Remove connector, (depending on model either screw-type
or tension clamp).
2. Press locking clips on both sides of the enclosure.
3. Pull out the circuit board.
Warning!! The circuit board can only be inserted in one position.
The connectors have been coded by the manufactur-
er, ensuring that they cannot be reversed.
3.3 Labelling possibilities
(Page 47, Fig. 3)
WS 10 connector markers can be used to label module.
13