Limiting the Maximum Water Temperature (see Figure 2)
The max. water temperature can be fixed from cold to the mid-range area of the adjustment range. This is done as
follows:
– Turn the temperature regulating handle (25) so that the wing points downward.
– Unscrew the locking screw (26) for the temperature regulating handle, using a 2 mm Allen key.
– Pull off the temperature regulating handle.
– Remove the interlock disc (27) and turn it 180°.
– Replace the interlock disc so that the locking pins completely enter the corresponding holes (28) in the valve housing.
– Install the temperature regulating handle with the wing down.
– Screw in the locking screw for the temperature regulating handle.
Cleaning the Filter (see Figure 2)
If the water flow has decreased, this may be because the filter is clogged. Clean the filter as follows:
– Shut off the water supply to the faucet.
– Unscrew the strainer (18) from the valve housing.
– Clean the strainer under running water.
– Screw the strainer back.
Troubleshooting
Symptom
Water flow from the outlet does
not stop, or stops after 2 minutes
Water flow is low and weak
No water comes out of the faucet
Cause / Solution
– The sensing range is too low
– Check that the photocell is clean
– The solenoid valve is damaged
– Filter is clogged
– Check the water supply to the control box
– The solenoid valve is damaged
– Power failure
– The photocell is covered or damaged
– 6105 and 6135: the showerhead is not placed
properly in its wall bracket
– Check the fuse (17) inside the control box:
6104 and 6105: 0.1 A
6134 and 6135: 1 A