Vent-Free/Wood Stove Blower Information
This blower is a reciprocating type blower. It is designed to direct heated air radiating from the rear of the stove to the
front at a low velocity. DO NOT expect a large volume of air to be felt when standing in front of the stove.
The blower is NOT thermostatically controlled. The blower speed is manually controlled by rotating the speed control
obtained by rotating the speed control knob clockwise. When routing the power cord, be sure that the cord does not
come into contact with any hot surface.
Operating Voltage is 110 to 120 VAC at 60 Cycle.
IMPORTANT :
stove, turn the blower off for approximately
30 minutes. The stove will require time to
reach the required temperature for proper
combustion.
IMPORTANT :
gasket are oriented correctly. The blower
wheel and gasket cut-ot must align with the
cut-out in the rear heat shield. Fasten the
blower and gasket to the rear heat shield
using the four (4) screws provided.
DO NOT over tighten screws. Be sure to
plug the blower into a 3 prong gounded
outlet. DO NOT tamper with the grounding
prong on the cord.
WARNING!
DO NOT submerge the blower into any
liquids. This will create an electric shock
hazard. Disconnect power before install-
ing or servicing unit.
CAUTION: Extreme caution is
necessary when any fan is used by or
near children or invalids and whenever
the fan is left operating unattended.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday.
IMPBAR - 2015-03-26
W a r m i n g Y o u r H o m e.
Vent-Free/Wood Stove Blower Installation
and Operating Instructions
MODEL #PBAR-2427
When refuelling your
Ensure the blower and
or email us at customerservice@ghpgroupinc.com
W a r m i n g Y o u r H e a r t.
For installation with
Pleasant Hearth Vent-Free/Wood Stove
Installation
The blower is to be installed at the rear of the stove,
on the rear heat shield. Align the blower and gasket
mounting holes with those on the rear heat shield.
Blower
Screws
Speed Control Knob
Blower
Screws
Speed Control Knob
Cleaning
Periodic cleaning of the blower is recommend-
ed. Dust or dirt accumulation could significant-
ly restrict airflow. Restriction in airflow will
reduce the efficiency of the blower and
possibly damage the motor.
Printed in China
Knock-Out Panel
Remove Prior to
Blower Installation
Back of Stove
Gasket
Wood Stove manual drawing
Electrical Cord
120V AC
Back of Stove
Gasket
Electrical Cord
120V AC
6440 W. Howard St.
N i l e s , I L .
6 0 7 1 4 - 3 3 0 2