en
8
➤ Place the cleaned filter inserts (8)/(9) into the
frame (7) with the correct side facing upward.
➤ Slide the filter unit into the guide and allow the
latch (11) to engage.
➤ Shut and lock the door.
Repair and customer service.
Repairs may be carried out only by qualified per-
sons in conformity with the valid regulations.
For repairs, we recommend our FEIN customer service
centre, the FEIN authorised service centres and FEIN
agencies.
Carry out the following maintenance regularly:
➤ Empty the collection receptacle and clean the filter
inserts.
Replace the filter inserts in time when the extrac-
tion performance decreases.
➤ Remove any deposits from within the housing.
Warranty and liability.
The warranty for the product is valid in accordance with
the legal regulations in the country where it is marketed.
In addition, FEIN also provides a guarantee in accordance
with the FEIN manufacturer's guarantee. For further
details on this, please contact your specialist dealer, your
national FEIN representative, or the FEIN customer serv-
ice centre.
Declaration of conformity.
GRIT declares itself solely responsible for this product
conforming with the relevant provisions given on the last
page of this Instruction Manual.
Original language English/German
Environmental protection, disposal.
Stationary machines should be sorted for environment-
friendly recycling in accordance with national laws.
Noise emission values (GIXBE).
A-weighted emission pressure power level measured at
the workplace L
(re 20 µPa), in decibels: 76
pA
Measuring uncertainty K
Measured A-weighted sound power level L
in decibels: 90
Measuring uncertainty K
REMARK: The sum of the measured emission value and
respective measuring inaccuracy represents the upper
limit of the values that can occur during measuring.
Wear ear protection!
Measured values determined in accordance with the cor-
responding product standard (see last page in this
Instruction Manual).
, in decibels: 3
pA
(re 1 pW),
wA
, in decibels: 3
wA
Specifications.
Type
Reference number
9 90 0..
Blower speed [rpm]
Power input [W]
Voltage [V]
Frequency [Hz]
3
Air flow [m
/h]
Extraction vacuum [Pa]
Weight according to
EPTA-Procedure
01/2003 [kg]
Class of protection
Connection diagrams.
Type GIXBE, Appendix 41
GIXS
GIXBE
..1 002 00 0
..1 009 00 0
– 2 880/3 450
–
370
–
3x400/
3x440
–
50/60
–
490
–
265
20
–
I/