Wiring Instructions - Ecco EW4010 Snow Plow Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Indicator Installation:
Each kit includes 1 indicator light per flood light which can be installed
on top or either side.
To assemble the indicator on the flood light, start by removing the M3
screws and indicator port cover. Connect the indicator wires to the flood
light and cover the connection in dielectric grease to reduce exposure to
the elements.
Install the indicator as shown in Figure 1 and secure in place with the
two M4 screws included using a 3mm hex key.
NOTE: The amber indicator functions only as a turn signal.
FIGURE 1
Bracket Mounting:
1. Select a mounting location for the unit on a flat surface and drill a 15/32"
hole.
2. Secure the light head with the supplied hardware by using the M5 screws
and lock washers as shown in Figures 2 or 3.
Aiming Instructions:
Installer is responsible for ensuring the snowplow lights are aimed properly
such that beams comply with current highway regulations. Beams should
project the same distance ahead as compliant OEM headlights.

Wiring Instructions:

Important! Disable power before wiring the product.
The wiring configuration is as shown in Figure 4. All wiring should be a
minimum of 16 AWG. The positive line must have a slow blow 25 or 30
amp fuse. Routing the ground wire directly back to negative battery ter-
minal is recommended. Pack dielectric grease, such as Dow Corning
4, around each electric connection exposed to moisture or the ambient
environment.
Ground (-) (Black)
High Beams (Red)
Low Beams (Yellow)
Parking Light (Green)
Indicator Light (Grey)
Not Used (Blue)
Ignition
Switch
25A In-line
Fuse
FIGURE 4
MOUNTING SURFACE
FIGURE 2
MOUNTING SURFACE
FIGURE 3