Functions of the terminal boards
VAS/101-CM
OPTIONAL:
Bus module
2 auxiliary exits
Relay 1
NO
C
Relay 2
NO
C
VLS/300
Adjustments
speak audio
microphone audio
electric lock 1-10 s. default 1 s)
Programming
y For call programming, see the entry panel documentation.
M2
M1
BOUT
X 5
beep
a
b
c
d
M1
M2
–
+
– +
B
B
Distances
VAS/101
PROG
SW3
Accessing programming Press the button
programming has been accessed a.
Programming the melody associated with the call from the entry panel (1 acoustic signal). To listen to
the melodies in sequence, press the button b. To select the melody and exit programming, press the button
c. To select the melody and continue with programming, press the button
Programming the melody associated with the doorbell (2 acoustic signals). For this type of program-
ming b c d proceed as previously described for "Programming the melody associated to the call from the
entry panel".
Programming the number of call rings (3 acoustic signals). press the button the number of times equal
to the number of rings selected for the call (from 1 to 6 rings) e. 3 s after the button is pressed the last time,
the call selected for the selected number of rings will be will be reproduced. To save the melody and exit
programming, press the button
e
M2
M1
BOUT
La
Technical features
Power supply: 16-18 VDC
Absorption: 120 mA max (75 mA stand-by)
Dimensions: 99x207x30 mm
Lb
Storage temperature: -25 °C +70 °C
Operating temperature: -15 °C +50 °C
IP degree: IP 54
five times within 5 s. A brief acoustic signal will confirm that
f.
f
PROG
Terminal board
Bus
BOUT
(not polarised)
SW3
+
Power supply
16-18 VDC
–
–
Earth
Door release
button (NO)
Electric lock
12 V 1 A max
–
Distances
2x2.5
2x1 mm
UTP/CAT 5
2
mm
La
≤250 m
≤250 m
–
Lb
≤25 m
–
≤60 m
d.
2
EN
5