Offset; Fil Pilote; Reset; Error Messages - Warmup WA-XSTAT-V Manual De Usuario

Ocultar thumbs Ver también para WA-XSTAT-V:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

raised. The adaptive function finds out when the
thermostat shall start heating to ensure that the
right temperature is reached at the time that it
has been programmed for.

6.7.4. Offset

Offset is used to compensate for any difference
between the thermostat and a room
thermometer. If the thermometer, for instance,
shows 1°C more than the thermostat, it is
possible to adjust the offset by +/- 5°C. Then
the thermostat will show the same temperature
as the thermometer. If the thermostat for
example shows 1 degree too much, offset
should be set to +1. Then the temperature will
be set 1 degree lower.
Offset applies to both built-in and external
sensors whereas the limit sensor, if any, is not
affected.

6.7.5. Fil Pilote*

Here you can specify temperature settings that
will depend on which signal is received from the
Fil pilote input.
*Please note: The Fil pilote menu is only
available in type WA-XSTAT-VB. It is primarily for
usage in France.
• Eco Temp: Economic temperature
• Frost Prt T: Frost protection
• Fil Pilote: On/Off

6.7.6. Reset

• Reset 2: Reset values defined in Engineer
settings to factory settings.
• Reset 3: Equal to Reset 2, except history
data are deleted. The number of relay
connections is not deleted, though.

7. Error Messages

If you get an error the LED is flashing red.
Internal failure
Contact Warmup
External failure Contact Warmup
4

8. Factory settings

The thermostat is delivered with factory set programs as follows:
Day 1-5
Event
Day
06:00-08:00
Out
08:00-16:00
Home
16:00-22:30
Night
22:30-06:00
Day 6-7
Event
Day
08:00-23:00
Night
23:00-08:00

9. Appendix

9.1. Table of Compatibility

Tiles
Stone
Wire
YES
YES
Ribbon Wire
YES
YES
Carbon
YES
YES
Central heating
n/a
n/a
Type A
YES
YES
Type B
NO
NO
Type C
NO
NO
n/a
n/a
User Defined

9.2. Heat Definitions

Tiles
Stone
A
Wire
Ribbon Wire
A
Carbon
A
Central heating
G
Type A
D
Type B
n/a
n/a
Type C
n/a
n/a
User Defined
H
Configuration
Min. Max.
A
B
C
D
E
F
G
H
n/a = not available
Time
With floor sensor
25°C
20°C
27°C
20°C
Time
With floor sensor
27°C
20°C
Laminate
Wood
Carpet
NO
NO
YES
YES
YES
YES
n/a
n/a
NO
NO
YES
YES
NO
NO
n/a
n/a
Laminate
Wood
Carpet
A
n/a
n/a
A
B
B
A
B
B
G
G
G
D
n/a
n/a
E
E
n/a
n/a
H
H
H
Control temperature
Room
Floor
Min. Max.
5
30
5
40
5
27
5
27
5
25
5
25
5
30
5
50
5
27
5
45
5
25
5
35
5
30
n/a
prog
prog
With air sensor
20°C
15°C
22°C
15°C
With air sensor
22°C
15°C
Vinyl
Other
NO
NO
n/a
NO
NO
n/a
YES
YES
n/a
n/a
n/a
n/a
NO
NO
n/a
NO
NO
n/a
YES
YES
n/a
n/a
n/a
n/a
Vinyl
Other
n/a
n/a
H
n/a
n/a
H
C
C
H
G
G
H
n/a
n/a
H
n/a
n/a
H
F
F
H
H
H
H
Overheat
Max.
40
30
30
55
50
40
n/a
prog

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido