Additional advice:
The removed control unit has no IP degree of
protection.
During installation, use spanner flat at the feed pipe
(wrench size SW27) as a back rest.
The service unit must not be dismantled.
CAUTION
malfunction during operation!
Through incorrect installation and poor maintenance,
malfunction may occur at the ENL 2.
Condensate which is not discharged may cause
damage to plants and in production processes.
The ENL 2 is an electronically level-controlled
condensate drain for compressed-air plants.
The device is employed within the permissible
performance parameters (see "Technical data").
The ENL 2 is able to drain condensate under operating
pressure from the plant components virtually without
compressed-air loss.
For its function, the ENL 2 requires an supply voltage
and an operating pressure (see "Technical data").
The ENL 2 as a condensate drain alone cannot
guarantee a defined compressed-air quality, for
this purpose, other additional technical devices are
required.
ENL 2 is not suitable for use in plants carrying vacuum
or atmospheric ambient pressure or in ex-areas.
ENL 2 must not be exposed to permanent direct solar
or thermal radiation.
4

3. PROPER uSE

4. ExCLuSION FROm ThE SCOPE OF APPLICATION

ingersollrandproducts.com
measures:
Condensate drainage which is reliable in performance
directly optimizes the compressed-air quality.
To prevent damage and breakdowns, it is imperative
to observe the following:
a.
Exact compliance with the specifications of use
and with the performance parameters of the
b.
ENL 2, in connection with the case of application
(see "Proper use" section)
c.
Exact compliance with the installation- and
operation instructions in this manual
d.
Regular maintenance and control of the ENL 2 in
accordance with the instructions in this operating
manual.
As far as the employment in plants with increased
demands on compressed air is concerned (food
industry, medical technology, laboratory equipment,
special processes etc.), the operator must decide on
measures for the monitoring of the compressed-air
quality. These have an effect on the safety of the
subsequent processes and may prevent damage to
persons and plants.
It is the task of the operator to ensure that the
indicated conditions are met during the entire
operating time.
ENL 2 must not be installed and operated in areas with
an aggressive atmosphere.
The ENL 2 is not heatable and, therefore, not suitable
for the use in areas where frost is likely to occur.
The ENL 2 is not suitable for CO2 plants.
80442866