1. Introduction
Thank you for purchasing this product. This series is equipped with 8 AVR-protected output
receptacles. AVR-protected socket will automatically maintain a constant voltage level to protect
sensitive electronics from brownouts and overvoltages. With its fashionable cabinet, it can be
installed on a desk or wall without causing an unsightly or unprofessional image, and will perfectly
utilize a limited working environment.
Features:
Provides 8 AVR-protected sockets
Provides stable output voltage through boost and buck stabilizer
Accepts wide input voltage range
Provides over-voltage and overload protection (option)
2. Product Overview
Power switch
Power LED: green lighting
AVR LED: yellow lighting
A VR-protected output receptacles
3. Installation and Initial Startup
Inspection
Remove the unit from the shipping package and inspect it for damage that may
occurred during transportation. Notify the carrier and place of purchase if any
damage is found.
Placement & Storage Conditions
Install the unit in a protected area that is free of excessive dust and has adequate air flow. Please
place the UPS away from other units at least 2.5cm to avoid interference. Do NOT block the top or
side air vents on the unit. Do not operation the unit in an environment where the ambient
temperature or humidity is outside the limits listed in the specifications. Operate the unit in an
environment free of excessive dust, mechanical vibration, inflammable gases and explosive or
corrosive atmospheres.
Connect to the Wall Outlet
Plug the input power cord of the unit to the wall outlet.
Connect the Loads
The AVR-protected receptacles will provide stable power to connected devices by boosting and
bucking the input power.
Turn On/Off the Unit
Turn on the unit by pressing the power switch to "RESET" (l)position. Then all connected
devices will be powered on.
Automatic Voltage Regulator
AC input
USB 5V DC
Computer Monitor Printer
4. Mounting Unit
The unit can be mounted to a wall surface. There are two ways to position the unit: vertically and
horizontally.
1. Use a ruler to draw a straight line in 140 mm vertically or horizontally on the wall.
2. Use a sharp nail to puncture the center of the two ends to mark the wall.
(see below chart 1 as placing the unit horizontally)
3. Mount the unit by positioning the key-hole slots over the mounting nails. (see chart 2 and chart
3)
Chart 1
180 mm distance between 2 holes
5. Applications
CAUTION: The total power consumption of all equipment plugged into the voltage regulator
must not exceed its capacity*. A total load in excess of its capacity* will cause the fuse to fault
(blow).
*For the capacity of unit, please check the specifications.
The voltage regulator is designed for use with voltage sensitive equipment such as: a home
computer, monitor, inkjet printer, scanner or fax. It is also designed for use with home
electronics equipment such as television, stereos, CD players, VCRs, and DVD players, data
processing equipment, modems, typewriters, calculators, and telephone equipment.
Appliances not suitable for use with the product are items such as freezers, power tools, air
conditioners, dehumidifiers, blenders, or any device that employs an AC motor for operation.
Not for use with small fuel generators. Also excluded are life sustaining equipment.
When use the voltage regulator with an
the output of this product, then connect the product to the wall outlet.
6. Important Safety Warning (SAVE THESE INSTRUCTIONS)
To safely operate this voltage regulator, please read and follow all instructions
carefully. Read this manual thoroughly before attempting to unpack, install, or
operate. You may keep this quick guide for further reference.
CAUTION: The unit is designed only for use under the 60 Hz input frequency and pure sine
wave environment. Any other input frequency or wave form will effect the voltage range and
load capability.
CAUTION: Please DO NOT connect the unit to the environment with direct voltage or
simulated sine wave.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the
acceptable temperature and humidity range.)
7 Specifications
Model
CAPACITY
INPUT
Voltage
Voltage Range
Frequency
OUTPUT
Voltage Regulation
Output Receptacles
INDICATOR
Power LED
AVR LED
PHYSICAL
Dimension (DxWxH)
Net Weight (kgs)
Environment
Humidity
Noise Level
Chart 2
Chart 3
Mounting horizontally
Mounting vertically
Uninterruptible
Power Supply (UPS), connect the UPS to
Power 1200
1200 VA / 600 W
120 VAC
93 - 147 VAC
60 Hz
± 10%
8
Green lighting
Yellow lighting
248 x 90 x 87.5 mm
1.5
0-90 % RH @ 0-40° C (non-condensing)
Less than 40 dB
Quick Guide v.1.1