Features
• Easy installation with strip terminal
• Adjustable output
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50 o C
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V, 15V and 24V
• Foldback Current Limiting Overload Protection
with Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Number
SLS-05-030-1T
SLS-12-017T
SLS-24-012T
o
Operating Temperature Range
0 to +50
Temperature Coefficient (Typical)
+/- 0.01% /
Stability
Within +/- 0.05% (24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
EMI/RFI
Linear power supplies have inherently low conducted and radiated noise levels.
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Cooling
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Multi Input (all units)
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
Transient Response Time
50 µ at 50% load changes for outputs rated up to 6A
100 µ at 50% load changes for outputs rated 6A and over
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
Line Regulation
0.05% for +/- 10% change
Load Regulation
0.05% for 50% change
Ripple
3.0 mV maximum peak-to-peak
DC Output Adjustment Range
+/- 5% minimum (Check Voltage & Current ADJ Placement Diagrams)
Overvoltage Protection
All 5 volt outputs include built-in OVP as standard (setting is 6.2V +/- 0.4V).
OVP is optionally available on other outputs
Remote Sensing
All units listed have remote sensing capability.
Overload Protection
125 to 150% foldback current limit
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Models: SLS-05-030-1T, SLS-12-017T,
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Limited Warranty for two years
• UL Recognized
• CSA Certified
• CE Marked
• CB Certified
Output
5V/3.0A
+12V/1.7A or +15V/1.5A
+24V/1.2A
C (Derate to 40% at +70 o C)
o
C
Input Specifications
Output Specifications
Output Installation
Step 1: Check the input AC connections
Step 2: Connect the AC input according to table below.
Note:
SLS-12-017T can be set to a +12V to +15V range by adjusting R11 V. ADJ.
SLS-24-012T
Input AC Connections (See Case A)
For use
at:
100 VAC
120 VAC*
220 VAC
230 VAC
240 VAC
*Note: Unit is shipped for 120V input from factory.
Mechanical Dimensions: Inches (mm)
5
1
3
2
4
Placement
.450" (11.5) MAX
Note: T he DC output can be adjusted with V. ADJ.
Application Note: U ser needs to provide earth ground to power supply with either solder to Tab or using washer and
nut assembly.
The SLS power supply is shipped from the factory with metal shorting straps connected between
the + OUT and + S terminals and the (-) OUT and (-) S terminals. This strapping configuration
allows the output of the SLS to be taken from either pair of terminals. This is the
standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the
individual OUT and S terminals to the appropriate points of the load. If an OVP circuit is used it
should be connected to the + OUT and (-) OUT terminals. The OVP should never be connected
to the + S, - S terminals without the use of the shorting straps. In all cases it is critical that the
terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Connect
Apply AC to:
Primary Fuse
SLS-05-030-1T
1-3, 2-4
1 & 5
0.5A / 125V
1-3, 2-4
1 & 4
0.5A / 125V
2-3
1 & 5
0.25A / 250V
2-3
1 & 4
0.25A / 250V
2-3
1 & 4
0.25A / 250V
4.843" (123)
1.62" (41)
0.48" (12.2)
4.142" (105.2)
. 744" (18.9)
AC INPUT/
DC OUTPUT
Please
See
OVP
(OPTIONAL)
Voltage
&
Current
ADJ
Diagrams
0.188"
MTG HOLES (6 PLACES)
°
(4.8)
WEIGHT: 2.43 LBS.
(1.1 KG)
PEM NUT HOLES
6-32 MTG (4 PLACES)
Case A
I. LIM is factory set on all models and should not be adjusted by users.
Visit our website at www.solaheviduty.com
Primary Fuse
SLS-12-017T
SLS-24-012T
1.0A / 125V
1.0A / 125V
0.5A / 250V
0.5A / 250V
0.5A / 250V
Voltage & Current
ADJ Placement Diagrams
R10
V. ADJ
R4
I-LIM
ADJ
SLS-05-030-1T
R11
V.ADJ
R3
I-LIM
ADJ
SLS-12-017T
SLS-24-012T