ELECTRONIC CONTROLS
DEFAULT SETTINGS (con't)
The LED default setting for the internal temperature is
the ambient (room) temperature measured at the time
the unit is connected or power is restored.
The LED default setting for the set operating
temperature is 41°F/5°C - we recommend you set the
temperature to 37°F/2.8°C to start, then adjust if
needed. Note: After a power failure has occured, the
previously set temperature is automatically erased
and will have to be re-set).
The LED default setting for temperature selection
(°F/°C) is °F (Farenheit Scale).
SETTING OPERATING TEMPERATURE: To set/change
the operating temperature:1) Press and release either of
the
(temperature) keys.
The LED display will temporarily revert to the (flashing)
set temperature for approximately 5 seconds (if you fail
to set/change the operating temperature within this 5
second period, the LED will automatically revert back
and display the internal temperature.
2) Each depression of the
mode) will increase the temperature incrementally
by 1° (temperature ranges between 36°F - 46°F
(2°C - 8°C)
3) Each depression of the key
mode) will decrease the temperature incrementally by
1°; temperature will display for approximately 5 seconds
after the selection is made, then revert back to display
the current internal temperature.
TEMPERATURE SELECTION (°F/°C): This unit can
display temperatures in the "Fahrenheit" or "Celsius"
scales. Press the temperature selector keypad to
alternate between °F/°C scale. The blue indicator
light adjacent to the corresponding mode (the mode
indicator light) will illuminate to signify the selection
made.
DEFROSTING: Your refrigerator is designed with an
"Auto-Cycle" defrost. What is Auto-Cycle Defrost?
The refrigerated surfaces of the fresh food
compartment defrost automatically during the "off"cycle
of the thermostat. Defrost water from the fresh food
compartment is disposed of automatically by means of
being channeled onto a drip tray located on the com-
pressor. Heat transfer from the compressor causes the
defrost water to evaporate.
OPERATING INSTRUCTIONS
key (during flashing
(during flashing
To turn "off" the refrigerator permanently, you must dis-
connect the power cord from the electrical outlet. There
is no "off" position (setting) available on the electronic
control panel.
NOTE: Wait 3 to 5 minutes before restarting if
operation has been interrupted (i.e. due to power
failure).
Changing the temperature display;
• Press the selector button
between Fahrenheit and Celsius. The corresponding pilot
light adjacent to the selector will aluminate to signify which
unit of temperature has been selected for display.
* Please Note: In the event of a power failure,
any modified settings are lost and the default
settings are restored once power resumes.