Quick Start Up Guide
4-
Standard profile operating method
The standard profile mode behavior is controlled; according to the IPC
J-STD-20 recommendations. Heaters power level controlled as well and
operating sequences between the upper heater, middle heater and side
heaters.
Profile is only running when two thermocouples are connected,
if one thermocouple connected process will not start.
Thermocouple (TC1) should place near the targeted component
and thermocouple (TC2) placed underside the PCB below the
component.
The table below shows the temperature ranges for each
profile stage in both Leaded and Lead Free profiles.
Pre-heat Temperature
Range
Soaking Temperature
Range
Peak Temperature Range
Maximum Dwell time
6
Jovy Systems® Limited
Leaded Profile
90◦C to 135◦C
140◦C to 180◦C
195◦C to 245oC
250 seconds
(Table -1)
RE-8500
Lead Free Profile
120◦C to185◦C
190◦C to 215◦C
220◦C to 270◦C
250 seconds