Error codes
E0: Internal fault. The thermostat must be replaced.
E1: Built-in sensor defective or short-circuited. Replace the ther-
mostat, or use the floor sensor only.
E2: External sensor disconnected, defective or short-circuited.
Reconnect the sensor if disconnected, or replace the sensor.
E5: Internal overheating. Inspect the installation.
CE marking
According to the following standard:
LVD/EMC: EN 60730-2-9
Classification
Protection from electric shock must be assured by appropriate
installation. Appropriate installation must meet the requirements of
Class II (enhanced insulation).
Environment and recycling
Please help us to protect the environment by disposing of the
packaging in accordance with national regulations for waste
processing.
Recycling of obsolete appliances
Appliances with this label must not be disposed of with
general household waste. They must be collected
separately and disposed of in compliance with local regula-
tions.
10
© 2015 OJ Electronics A/S
English
OCD5-1999

TECHNICAL DATA

Voltage ........................................................................ 100-240 VAC
Max. pre-fuse .............................................................................16 A
Built-in circuit breaker .................................................. 2-pole, 16 A
Output relay ........................................... make contact - SPST - NO
Output .............................................................................. max. 16 A
Terminal wire size ......................................................... 1.5-2.5 mm2
Control principle .................................................................. PWM/PI
Standby power ........................................................................
Battery backup ..................................................................... 5 years
Action type .................................................................................. 1.B
Software class .................................................................................A
TB ............................................................................................ 125°C
ELV limits realized ............................................................. SELV 24 V
Pollution degree rating..................................................................... 2
Rated impulse voltage ............................................................... 4 kV
Enclosure rating ........................................................................ IP 21
Dimensions .................................................... H/82, W/82, D/40 mm
Build-in depth ........................................................................ 23 mm
Display ......................................
EU registered design ....................................................
The thermostat is maintenance free.
176x220 pixel TFT - resistive touch
© 2015 OJ Electronics A/S