Descargar Imprimir esta página

Trouble Shooting Guide - Excell VR1600E Manual De Instrucciones

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
Motor will not
start and there
is no humming
sound
Power
source circuit
continues to
trip or blow
fuses
Motor hums but
will not start
No or low
pressure
Excess noise
Pressure
fluctuates with-
out open ing gun
GFCI switch indi-
cator light does
not appear after
depressed
GFCI test fails
Unit does not
maintain steady
water pressure
Unit continues
to trip GFCI
switch

TROUBLE SHOOTING GUIDE

CAUSE
Pressure washer not plugged in.
"RESET" button on GFCI not
pushed.
Circuit breaker has tripped or fuse
is blown.
Too much load already on circuit.
Using an extension cord.
Using an extension cord.
Supply voltage below required
minimum.
Low water supply.
High pressure hose is too long.
Worn nozzle.
Restricted, insufficient water
supply, or air in the water line.
Water temperature is too high.
Water leak in high pressure fittings,
hose, or gun.
Circuit breaker has tripped or fuse
is blown.
Circuit breaker has tripped or fuse
is blown.
Nozzle clogged
Nozzle clogged
Plug in pressure washer.
Push "RESET" button.
Reset breaker or replace fuse.
Reduce load on circuit.
Try another 15 amp circuit.
DO NOT use extension cords.
DO NOT use extension cords.
Check the voltage of the main
supply line.
Water supply must be at least 5
GPM @ 20 psi.
Use high pressure hose under
100 feet.
Replace nozzle.
Check supply hose, faucet, and
inlet screen.
Do not use water from a hot
water source, use water only from
a cold water faucet.
Replace hose or gun. If problem
continues take to authorized
service center.
Reset breaker or replace fuse. If
indicator light still does not appear
have receptacle checked by a
qualified electrician.
Reset breaker or replace fuse. If
indicator light still does not appear
have receptacle checked by a
qualified electrician.
Clean nozzle, if unit still does not
maintain steady water pressure,
turn unit off and contact customer
service at 1-866-422-4286
Clean nozzle, if unit still does not
maintain steady water pressure,
turn unit off and contact customer
service at 1-866-422-4286
17 - ENG
CORRECTION
A17913

Publicidad

loading