TECHNICAL SPECIFICATIONS
NOT-PREMIUM rev 02
Input
Tension
Frequency
Cos phi
Efficiency
Mains consumption
Fusible
Output
Nb of outputs
Nb charginig curves
Curves types
Charging
profiles
(Diagram A)
Diagram B :
12V 10A 12V 15A 12V 25A 12V 40A 24V 20A
230V +/- 15%
115V please
consult us
50Hz - 60Hz (+/- 10%)
0.6 typ
1.3A
1.9A
T2A
T3, 15A
250V
220V
5x20mm
5x20mm
3 isolated outputs
4 possible charging curves.
Selection by external dip-switch
IUUo & automatic weekly equalization
Button – Night Mode
115V - 230V
(+/- 15%)
0.9 typ
80% typ
4A/2A
7A/3.5A
T6A
250V
5x20mm
5x20mm
UK
T10A
250V