4.
TECHNICAL DETAILS
230 V~
F1= F315mA
4.1 Controls
0
3 N.O. OPENS
It activates the opening operation. NOTE: During the
opening operation a 0-4 control causes the wing to stop.
0
4 N.O. CLOSES
It activates the closing operation. NOTE: During the
M
closing operation a 0-3 control causes the wing to stop.
=

4.2 Motor connection

M
Connect the motor to the control panel by means
of the 2-wire 24V DC motor power supply cable
Fig. 9
(0.5 square mm / max. 3 m – 1.5 square mm /
max. 10 m).
To reverse the direction invert motor polarity.
4.3 Multi-level single and centralized controls
(Fig.1) Two or more automations of a house can be
opened and closed by means of a single couple of
centralized buttons (connected by means of diodes -
not supplied by us), without excluding separate control
of each automation from one's own push-button station.
5.
START
5.1 Connect any remote or centralized controls.
5.2 Connect 230V AC supply mains.
Fig. 10
5.3 With a series of opening and closing controls,
make sure the automation is working properly.
NOTE: OLLY E automation is not reversible, however,
in order to ensure a proper closing at night, the
OKAMCJE lock device must be fitted.
6.
MAINTENANCE (every 6 months)
Cut the 230V ~ power supply.
- Check the fastening of the fixing screws and belt
tension.
- Check all electrical connections.
Provide 230V ~ power supply.
- Check the automation is working properly.
All right reserved
All data and specifications have been drawn up and checked with
the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data
due to technical or illustrative purposes.