750 lb. & 1000 lb. Carrier Installation
Note: Follow the installation sequence for 500 lb. carriers, with the exceptions below.
1.) 750 lb. and 1000 lb. carriers are supplied with a rear anchor bar that must be
secured with two 1/2" dia. anchor bolts (supplied by others).
2.) The nipple and rods for 750 lb. and 1000 lb. carriers cannot be extended beyond
the maximum dimension of the factory supplied assembly.
Carriers for Floor Mounted Back Outlet Bowls (suffix -BF)
Note: Carriers for floor mounted back outlet bowls are used to transition from
the bowl outlet to the sanitary piping system, and to form carrier batteries.
Follow the installation sequence for 500 lb. carriers, with the exceptions
below.
1.) -BF faceplate assemblies are supplied with a special plate to accommodate a
4"(102) rough-in for back outlet bowls. The bowl is secured to the carrier with two
attachment studs and chrome plated acorn nuts (provided).
2.) A rear anchor support is not required for -BF carriers.
5