Beta 1881 Instrucciones página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
Transport
• Weight and overall dimensions of the pump are indicated on page 24 - 25.
• The pump is ready for use and is packed in such a way that none of its components can be
damaged during transportation.
• The packaging must not be discarded into the environment.
• To store or transport a new pump does not require any special care nor does it involve any risks.
• If, after use, it is necessary to store, transport or dispose of the pump, the upper part of the
pumping system must be emptied by tipping it over and the lower part must be emptied by lifting
manually the bottom valve ball in order to avoid accidental leakage during movement.
• During this operation smoking is prohibited, the use of protective gloves is advised.
Do not operate near naked flames.
• The oil must be poured into a suitable container and disposed of in compliance with
current legislation.
Maintenance
• Change air exhaust filter when it clogs up, or after a maximum of 12 months.
• Check that there is no water trapped in the compressed air pipes of the system.
Operating problems,
Insufficient delivery:
If the problem continues consult an approved repair centre
solutions
Check that there is no air in the oil distribution system
( this problem may occur when drum is changed).
Check that pressure is not lower than 4 bar.
Check filters during suction and delivery phase as
well as the pneumatic engine air silencer/ muffler
8

Publicidad

Tabla de contenido
loading

Tabla de contenido