TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
❒ Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
NOTE: Sensor has a 1
before it will detect motion. When first turned
1
on, wait 1
/
minutes.
2
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
The detector is most sensitive to motion across its field
of view.
Motion
Least Sensitive
595-4884-17
1
/
minute warm up period
2
RANGE
MIN
70 ft.
(21 m)
Maximum
Coverage Angle
Motion
Sensor
Most Sensitive
❒ Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected).
Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
MAX
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . Up to 150°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
150°
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . 1 , 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
®
Heath
/Zenith reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
3
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
candescent [Up to 150 Watt
maximum each lamp holder.]