ENGLISH
Before commencing with the installation of this appliance make sure that you have read the following
instructions carefully. In particular familiarise yourself with the safety devices required by the system,
only then will you be able to use them to great effect.
Not all of the safety devices required by Italian or local safety standards have been taken into con-
sideration in this manual. The installer must therefore make sure that any eventual safety devices
required by the local standards and regulations have been installed both ahead of and after the
products described in this manual.
These instructions are aimed at professionally qualified "installers of electrical equipment" and must
respect the local standards and regulations in force .
This appliance must be used exclusively for the purpose for which it has been made. "i.e. for the
automation of gates and doors" Any non authorised modifications are to be considered improper
and therefore dangerous.
TECHNICAL SPECIFICATIONS
Power supply
Frequency
Number of possible motors
Overall motor power
Nominal electrical input
Operating temperature
Inputs
Power supply connection 230Vac 50/60Hz
Earth wire
Antenna entry point
Opening button in input "normally open contact"
Closing button in input "normally open contact"
Dynamic button in input "normally open contact"
Blocking button in input "normally closed contact"
Opening travel limit "normally closed contact"
Closing travel limit "normally closed contact"
Inversion photoelectric cells "normally closed contact"
Outputs
Output for: 1 or 2 motors connected in parallel; Overall motor power: 450W
Output for a timer controlled night light 230Vac 40W
Output for an electric locking device 12Vac 15W
Output for indicator lamps 24Vac 3W
Output for flashing warning lights 24Vac 10W
Output for radio receiver second channel contact C-NO (30W in dc or 60VA in ac)
Output powering external devices 24Vac 10W
Work time Maximum programmable time
Pause time Maximum programmable time
Night light
The total time is equal to: "opening time + pause time + closing time + 30 seconds"
REMARKS
V ac
230
Hz
50-60
Nr.
2
W
450
Amp
2,6
°C
-20...+55
seconds
seconds
10
ENGLISH
300
300