TROUBLESHOOTING
Office Pro 60 Self-Diagnostic Codes
Self-Diagnostic Codes will be displayed on the Control Board under
the following conditions:
TANK
FULL
SET POINT
SET TEMP
FAN ON/OFF
COOL ON/OFF
Check the following points before calling a qualified technician.
SYMPTOM
Unit does not operate
Insufficient cooling
If symptoms persist after the above actions have been taken, turn the
unit off, disconnect the power cord plug and contact your MovinCool
reseller.
F
AM
C
PM
ROOM TEMP
CLOCK/TIMER
HRS
MIN
START TIME
END TIME
SET CLOCK
SET
RUN
PROGRAM
Office Pro 60
POSSIBLE CAUSE
➀
Ground fault breaker tripped
➁
Drain tank is full
(FULL TANK LED will be
flashing)
➀
Dirty/blocked air filters
➁
Air inlet/outlet blocked
➂
Improper temperature setting
dF
When the evaporator freezestat
disengages the compressor.
FL
When the drain tank switch shuts
off the unit (FULL TANK LED
flashes).
AS
When unit disengages the com-
pressor while the condensate
pump is discharging water.
HP
When the high pressure switch
disengages the compressor.
LO
Lowest temperature set point.
19
REMEDY
Reset breaker
Empty the drain tank
Clean air filters
Clear air inlet/outlet
Set to desired position