SUPERIOR SLAVE
1
0-10
0-10
24VAC
VDC
GND
VDC
GND
2
2
1
2
GND
GND
24V
GND
23 24
25 26
25 26
1
1
1
2
2
24VAC
0-10V
24VAC
0-10V
MIX. POINT / OUTDOOR
MIX. POINT / OUTDOOR
POWER SUPPLY
Vanne/ Groupe Exterieur DX
Alimentation
Vanne/ Groupe Exterieur DX
Vanne/ Groupe Exterieur DX
UNIT DX
UNIT DX
MIX POINT
vanne
HEATER/
HEATER/
HEATER/
VENT-INT
VENT-EXT
PREHEATER
24VAC
24VAC
PREHEATER
24VAC
24VAC
REC/BYP
24VAC
POSTHEATER
REC/BYP
POSTHEATER
RPM
RPM
1
COOL/PUMP
COOL/PUMP
1
1
COOL/PUMP
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
GND
1
GND
PWM
GND
GND
1
PWM
GND
GND
~
~
2
~
~
2
0-10V
~
GND
GND
+SSR -SSR
~
+SSR -SSR
2
~
~
2
0-10V GND
0-10V GND
(TC)
~
~
2
0-10V
(TC)
GND
GND
0-10V
0-10V
GND
0-10V
13 14
15
16 17 18 19 20 21 22 23 24
25 26 27 28 29
30
31
32
33
25 26 27 28 29
34
25 26 27 28 29
30
31
32
33
34
35 36 37 38 39 40 41 42 43
FUSE
FUSE
(VENT-EXT)
(VENT-INT)
FUSE
FUSE
(PCB)
(PERIPHERY)
83
82
81 80 79 78 77 76 75 74 73
72 71
72 71
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
70 69
N
L
LO
L
LO
L
LO
N
ALARM
RUN
COOL/HEAT
ALARM
RUN
ALARM
RUN
COOL/HEAT
DEFROST EXTERNAL
N
ERROR
DEFROST EXTERNAL
ERROR
230VAC
230VAC
230VAC
230VAC
HEATER
OUTPUT
HEAT PUMP
HEATER
OUTPUT
HEATER
OUTPUT
HEAT PUMP
HEAT PUMP
HEAT PUMP
ON/OFF
PIR
FLAP-INT
FLAP-EXT
W. PUMP
230VAC
CONTACT
EXTERNAL
EXTERNAL
CONTACT
WATER
POMPE
CONTROL
CONTROL
EXTERNE
EXTERNE
PUMP CONTROL
DE CIRCULATION
OUTPUT
OUTPUT
OUTPUT
ON/OFF
ON/OFF
72 71
72 71
72 71
77 78
76 75
4
3
63 64
63 64
6
4
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
7
7
11
7
11
5
OUTLET
(Sortie pour unité
(Sortie pour unité
(Sortie pour unité
(Output for outdoor unit)
Registre
Commande
Commande
exterieure)
exterieure)
exterieure)
Air Rejeté
á distance
á distance
9
68 67
70 69
66 65
68 67
66 65
!
defrost
!
defrost
DX GENERAL ERROR
DX GENERAL ERROR
DX GENERAL ERROR
DX DEFROST
DX DEFROST
10
9
8
10
9
(settable)
(settable)
(settable)
(settable)
PRESENCE
CAPTEUR
PRESENCE
CAPTEUR
PRESENCE
CAPTEUR
PRÉSENCE
SENSOR
PRÉSENCE
SENSOR
PRÉSENCE
SENSOR
81 82 55 56
81 82 55 56
81 82 55 56
ver.2 10-01-20
VCS-R4-SU-
2
3
Control panel
Control panel
boitier de commande
boitier de commande
0-10
VDC
GND
24
23
22
20
19
25 26
49 50
49 50
EXT. SENSOR
EXT. SENSOR
3
EXT. SENSOR
2
3
Capteur Externe.
Capteur Externe.
Capteur Externe.
0-10V
(two-wire shielded cable)
(two-wire shielded cable)
MIX. POINT / OUTDOOR
(two-wire shielded cable)
Câble deux fils blindé
Câble deux fils blindé
Câble deux fils blindé
UNIT DX
J1/J2
J1/J2
PREHEATER
T-WATER T-WATER T-ROOM
24VAC
REC/BYP
POSTHEATER
T-WATER T-WATER T-ROOM
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
1
9
-OUT
-IN
~
~
2
0-10V
GND
+SSR -SSR
-OUT
-IN
0-10V GND
35 36 37 38 39 40 41 42 43
30
31
32
33
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
44 45 46 47 48 49 50
SWO
SWO
DATA
DATA
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
1
1
2
PRESENCE
PRESENCE
2
COOL/HEAT
IN GND
REC ERR
DEFROST EXTERNAL
IN GND
REC ERR
REC ERR
ERROR
FIRE
BOOST
FIRE
FIRE
BOOST
15VAC
SENSOR
15VAC
SENSOR
HEAT PUMP
ON/OFF
HEAT PUMP
ON/OFF
CO2/RH/EXT
CO2/RH/EXT
PIR
PIR
CONTACT
EXTERNAL
CONTACT
CONTACT
CONTACT
FIRE
FIRE
FIRE
CONTACT
CONTACT
ERROR
CONTROL
EXTERNE
ERROR
INCENDIE
INCENDIE
INCENDIE
CONTACT
ERREUR
CONTACT
ERREUR
BOOST
BOOST
ON/OFF
5 6
8
7
59 60
62 61
62 61
63 64
62 61
59 60
9
10
57 58
57 58
BOOST
BOOST
5
6
7
14
12
11
13
12
14
12
13
Commande
CMSI
CMSI
CMSI
á distance
SLAVE
SLAVE
68 67
66 65
1
6
1
CO
CO
2
2
15
EXTERNAL
EXTERNAL
2
7
!
2
defrost
3
8
3
DX DEFROST
10
9
53 54
53 54
4
9
4
(settable)
(settable)
2
2
5
10
5
GND
GND
2VV. Creating innovative solutions for you and your business since 1995.
S
E
VCS-R4-SU-
-SL
GTC
GTC
ou
ou
or
or
Control panel
boitier de commande
ModBUS RTU via
ModBUS RTU via
Rs485
Rs485
49 50
3
J1/J2
1
T-WATER T-WATER T-ROOM
2
-OUT
-IN
FILTER
FILTER
9
9
10
10
3
JP1
JP1
JP1
INT
INT
LED1
LED1
LED1
44 45 46 47 48 49 50
4
SWO
5
DATA
6
7
8
1
2
PRESENCE
IN GND
BOOST
15VAC
SENSOR
CO2/RH/EXT
PIR
CONTACT
ERROR
CONTACT
ERREUR
BOOST
59 60
11
57 58
BOOST
!
!
!
14
13
6
CAPTEUR 0-10V
CAPTEUR 0-10V
/ RH/VOC
/ RH/VOC
CAPTEUR 0-10V
SENSOR
SENSOR
CO
/ RH/VOC
2
16
16
15
15
EXTERNAL
7
8
51 52
51 52
53 54
9
1
2
1
1
A
0-10 VDC
V+
GND
0-10 VDC
GND
V+
V+
GND
CO
/RH/VOC/EXT
CO
/RH/VOC/EXT
15VAC
15VAC
15VAC
2
2
SENSOR
SENSOR
Capteur CO /HR
Capteur CO /HR
V
-SL
VCS-R4-SU-
GTC
ou
or
ModBUS RTU via
Rs485
LPHW sensor de salida (incluido en la entrega)
Conexión para unidad SLAVE
FILTER
9
10
Protección antihielo (NC)
INT
Control externo (entrada, ON/OFF)
Termostato (entrada, NO/NC)
Contacto DOOR (entrada, NO/NC)
Señal de control de la unidad MASTER
Control de la válvula de agua (0-10V)
SENSOR
16
51 52
0-10 VDC
GND
CO
/RH/VOC/EXT
2
SENSOR
Capteur CO /HR
-SL
in control module
24V
GND
0-10V
24V
GND
HEAT
0-10V
8
15