Detectors and External Speaker
The RX and TX can be plugged into either of the two 5-way DIN socket as the controller uses intelligent software to
determine which one has been connected.
Fig 4: Installation
An optional external speaker can be connected to the centre 2-way terminal block.
3. External Signals Wiring Examples
Door closing
signal and
common (0V)
Spare
contact on
door close
contactor
o o o o
13
Door opening
signal and
common (0V)
o o o o
13
14
15
16
Spare
contact on
door open
contactor
Common (0V)
14
15
16
Fig 5: Installation
Common can be joined
together at Panachrome
Door closing
signal and
common (0V)
o o o o
12 - 230VAC
13
or DC supply
+
Controller
Door opening
signal
14
15
16