RJ45 in Pin Define & Connection
Caution :
- FTP Category 6 cable is recommended to field construction.
- Input CAT 6 wire must be with standard RJ45 male connector.
- A workable length is not exceed 90 Meter CAT 6 cable from injector, no guaranty if CAT 6 cable beyond 90 Meter.
POE INJECTOR
138mm
HOUSING: RJ-45 Input (Data & Power)
Pin
Symbol
1
RX+, Vin +/-
2
RX-, Vin +/-
3
TX+, Vin +/-
4
Vin +/-
5
Vin +/-
6
TX+, Vin +/-
7
Vin +/-
8
Vin +/-
Description
Data Receive/ Feeding power (+/-)
Data Receive/ Feeding power (+/-)
Data Transmit/ Feeding power (+/-)
Feeding power (+/-)
Feeding power (+/-)
Data Transmit/ Feeding power (+/-)
Feeding power (+/-)
Feeding power (+/-)
POWER &