Troubleshooting Procedures - Whirlpool K-702 Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Sequence (cont.)
IMPORTANT! Please refer to your Homeowners Guide for detailed instructions on the user keypad and
remote control.
Press Power to turn on the whirlpool. The whirlpool will start at medium flow.
Increase or decrease the water flow by pressing either the up or down arrow buttons on the keypad.
An indicator bar in the center of the keypad shows the water flow volume.
Adjust each jet for optimum air/water mixture. Turn the jet trim clockwise to reduce the air flow,
and counterclockwise to increase the air flow.
Make sure the slip cover is in place on the pillow, and the pillow is attached to the neckjet body.
With the whirlpool operating, rotate the outer ring until the neckjet icon is flashing. Press "OK" to
activate the neckjets. The neckjet pulsing action will start at medium speed.
Increase or decrease the neckjet pulsing action by pressing either the up or down arrow buttons on
the keypad.
To activate or deactivate different modes while the neckjets are operating, rotate the outer ring until
the desired mode is flashing and press "OK". (Example: To turn the heater off, rotate the dial until
the heater icon is flashing and press "OK").
Press "OK" while the neckjet mode is flashing to turn off the neckjets.
Press the Power On/Off button a second time to turn the whirlpool off.
NOTE: A built-in timer automatically stops the pump and motor after approximately 20 minutes of
operation.

16. Troubleshooting Procedures

This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Troubleshooting the Whirlpool System
Symptoms
1. User keypad does not
illuminate when power button
is pressed or outer ring is
rotated.
2. Motor starts, but all jets are not
functioning.
3. User keypad is illuminated, but
does not respond to buttons or
outer ring.
1018963-2-C
Probable Causes
A. No power to control.
B. GFCI or ELCB tripped.
C. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
D. User keypad does not work.
E. Control does not work.
A. Jet is closed.
B. Jet not installed correctly.
C. Jets are blocked.
A. Control program is locked.
B. Wiring harness from user
keypad to control is loose,
disconnected or damaged.
C. User keypad does not work.
D. Control does not work.
14
Recommended Action
A. Check wiring and connect
power.
B. Reset GFCI or ELCB.
C. Check wiring for proper
connections. Replace wiring
harness if necessary.
D. Replace user keypad.
E. Replace control.
A. Rotate jet trim
counterclockwise to open.
B. Reinstall jet; check for O-ring
damage.
C. Remove blockage.
A. Reset GFCI or ELCB.
B. Check wiring for proper
connections. Replace wiring
harness if necessary.
C. Replace user keypad.
D. Replace control.
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido