Installation
Installation
NOTE: Flush the water supply line before
beginning installation.
Supplies Required:
• (3) 3/8" bolts and wall anchors for
mounting wall bracket
• Pipe sealant
• Piping to 1/2" NPT water supply inlet on
unit
• Piping to 1-1/4" NPT drain outlet for
eyewash
• Sign-mounting hardware
Step 1: Install inlet drain fittings
NOTE: The top of the eyewash heads should
be 33"–45" (838mm–1143mm) from the floor.
1. Position the inlet drain fitting over the 1-
1/4" drain outlet pipe from wall.
2. Using the inlet drain fitting as a template,
mark the bolt hole locations on the wall
OR install three suitable fasteners
(supplied by installer) for 3/8" bolts in
the wall at the marked hole locations (see
Figure 1).
3. Bolt the inlet drain fitting to the wall or
wall fasteners using 3/8" bolts (supplied
by installer).
Step 2: Assemble eyewash
components
1. Assemble eyewash components as shown
in Figure 2 on page 4.
• Apply pipe sealant (supplied by
installer) to all male-threaded pipe
joints.
• Use a strap wrench around pipes when
tightening to prevent marring.
Step 3: Connect water supply
1. Connect the water supply piping
(supplied by installer) to the 1/2" NPT
inlet on the eyewash.
2. Connect the tailpiece to the 1-1/4" NPT
drain outlet on the eyewash.
3. Mount the safety sign to the wall using sign-mounting hardware (supplied by installer).
4. Open the water supply lines. Test for leaks and adequate water flow.
Bradley Corporation • 215-158DC Rev. K; EN 06-532E
Wall
13-5/8"
(346mm)
Ø 10-3/4" (273mm)
21-1/2" (546mm)
8-3/4"
(222mm)
4"
(102mm)
Ø 5/16"
(8mm)
30-1/2"
2-1/4"
(775mm)
(57mm)
Suggested
Height
To Floor
Figure 1
4/17/07
S19-220DC
4-5/8"
(119mm)
8-1/4"
(210mm)
17-1/4"
(438mm)
5-1/4"
(133mm)
7-1/4"
(184mm)
(914mm)
Suggested
Height
To Floor
7-1/2"
(191mm)
36"